Application Note | Coin Surface Analysis
3D Surface Analysis of a Penny with Profilometry
Dimensional Analysis and Surface Subtraction of Five Pennies Minted in Different Years

Research & Experimental Testing
NANOVEA Laboratory
Visual Design & Editorial
Andrew Shore
Introduction
Currency is highly valued in modern society because it is traded for goods and services. Coin and paper bill currency circulates around the hands of many people. Constant transfer of physical currency creates surface deformation. NANOVEA’s 3D Profilometer scans the topography of coins minted in different years to investigate surface differences.
Why Non-Contact Profilometry Matters for Coins
Coin features are easily recognizable to the general public since they are common objects. A penny is ideal for introducing the strength of NANOVEA’s Advanced Surface Analysis Software: Mountains 3D. Surface data collected with our 3D Profilometer allows for high level analyses on complex geometry with surface subtraction and 2D contour extraction. Surface subtraction with a controlled mask, stamp, or mold compares the quality of manufacturing processes while contour extraction identifies tolerances with dimensional analysis. NANOVEA’s 3D Profilometer and Mountains 3D software investigates the submicron topography of seemingly simple objects, like pennies.
ℹ️ Learn more about non-contact profilometry lab services for stamped and minted parts.
Measurement Objective
The full upper surface of five pennies were scanned using NANOVEA’s High-Speed Line Sensor. The inner and outer radius of each penny was measured using Mountains Advanced Analysis Software. An extraction from each penny surface at an area of interest with direct surface subtraction quantified surface deformation.
Measurement Setup

| Measurement setup | Value |
|---|---|
| Instrument | NANOVEA HS2000L |
| Optical sensor | LS2 lens (1 mm Z-range) |
| Scan size | 20 mm × 20 mm |
| Step size | 10 µm × 10 µm |
| Scan time | 00:00:24 (h:m:s) |
A penny being analyzed with the NANOVEA 3D profilometer, and the measurement setup.
Results and Discussion
3D Surface
The NANOVEA HS2000 profilometer took only 24 seconds to scan 4 million points in a 20 mm x 20 mm area with a 10 µm x 10 µm step size to acquire the surface of a penny. Below is a height map and 3D visualization of the scan. The 3D view shows the High-Speed sensor’s ability to pick up small details unperceivable to the eye. Many small scratches are visible across the surface of the penny. Texture and roughness of the coin seen in the 3D view are investigated.

| ISO 25178 height parameter | Value |
|---|---|
| Sa | 33.492 µm |
| Sq | 44.600 µm |
| Ssk | 1.3685 |
| Sku | 4.9175 |
| Sp | 161.21 µm |
| Sv | 142.63 µm |
| Sz | 303.84 µm |
Table 1: Height parameters of the 1995 penny.

| ISO 4287 parameter (Gaussian filter, 0.8 mm) | Value |
|---|---|
| Ra | 12.47 µm |
| Rq | 13.85 µm |
| Rz | 44.37 µm |
| Rp | 22.47 µm |
| Rv | 21.90 µm |
| Rt | 54.33 µm |
| Rc | 41.64 µm |
Table 2: Profile roughness parameters for the 1995 penny (Rc per ISO 4287 without amendment 2).


Fig. 3: 3D views of the pennies.
Dimensional Analysis
The contours of the penny were extracted and dimensional analysis obtained inner and outer diameters of the edge feature. The outer radius averaged 9.500 mm ± 0.024 while the inner radius averaged 8.960 mm ± 0.032. Additional dimensional analyses Mountains 3D can do on 2D and 3D data sources are distance measurements, step height, planarity, and angle calculations.

| Year | Outer radius (mm) | Inner radius (mm) |
|---|---|---|
| 1969 | 9.476 | 8.961 |
| 1977 | 9.484 | 8.948 |
| 1985 | 9.488 | 8.966 |
| 1995 | 9.540 | 8.913 |
| 2007 | 9.514 | 9.011 |
| Average | 9.500 | 8.960 |
| Standard deviation | 0.024 | 0.032 |
Table 3: Outer and inner radius of the five pennies.
Surface Subtraction
Fig. 5 shows the area of interest for the surface subtraction analysis. The 2007 penny was used as the reference surface for the four older pennies. Surface subtraction from the 2007 penny surface shows differences between pennies with holes/peaks. Total surface volume difference is obtained from adding volumes of the holes/peaks. The RMS error refers to how closely penny surfaces agree with each other.


| Penny year | Surface volume difference (µm³) | RMS value |
|---|---|---|
| 1969 | 25862453 | 5.405 |
| 1977 | 39173134 | 8.182 |
| 1985 | 47427247 | 7.598 |
| 1995 | 18194986 | 4.756 |
Table 4: Surface subtraction results against the 2007 reference penny.
Conclusion
NANOVEA’s High-Speed HS2000L scanned five pennies minted in different years. Mountains 3D software compared surfaces of each coin using contour extraction, dimensional analysis, and surface subtraction. The analysis clearly defines the inner and outer radius between the pennies while directly comparing surface feature differences. With NANOVEA’s 3D profilometer’s ability to measure any surfaces with nanometer-level resolution, combined with Mountains 3D analysis capabilities, the possible Research and Quality Control applications are endless.
Frequently Asked Questions About 3D Surface Analysis of Coins
Why measure coins with a 3D profilometer?
Coins circulate through many hands, and constant handling creates surface deformation. A 3D profilometer scans the topography of coins minted in different years to investigate surface differences, and the same methods compare stamped or molded parts against a reference in manufacturing.
How fast is a high-speed 3D scan of a penny?
The NANOVEA HS2000 took only 24 seconds to scan 4 million points over a 20 mm × 20 mm area at a 10 µm × 10 µm step, revealing small scratches not perceivable to the eye.
What is surface subtraction?
An area of interest is extracted from each surface and the reference surface is subtracted from it. The volumes of the resulting holes and peaks give the total surface volume difference, and the RMS value shows how closely the surfaces agree. With a controlled mask, stamp or mold as reference, this compares manufacturing quality.
What did the surface subtraction of the pennies show?
Against the 2007 penny, the 1995 penny agreed most closely (18194986 µm³, RMS 4.756), while the 1985 penny differed most in volume (47427247 µm³, RMS 7.598) and the 1977 penny had the highest RMS (8.182).
How are the rim radii measured?
Contours are extracted from the scan and dimensional analysis measures the inner and outer radius of the edge feature. Across five pennies the outer radius averaged 9.500 ± 0.024 mm and the inner radius 8.960 ± 0.032 mm.
Which software analyzes the 3D data?
NANOVEA’s advanced analysis software, Mountains 3D, for contour extraction, dimensional analysis (distance, step height, planarity, angle), roughness and surface subtraction on 2D and 3D data.