Tribology testing · Corrosion module

Tribocorrosion Testing

Tribocorrosion is material degradation caused by mechanical wear and electrochemical corrosion acting together, and the combined loss is often greater than the two separately. The corrosion module runs a sliding wear test with the contact immersed in an electrolyte inside a three-electrode cell, so the electrochemical state of the surface is monitored, or controlled, while it wears.

Tribocorrosion electrochemical cell module for NANOVEA tribometers

At a glance

Configuration
Ball-on-plate sliding with the contact fully immersed in the test electrolyte.
Electrochemical cell
Three electrodes: the sample (working), a platinum wire (counter) and an Ag/AgCl reference electrode in saturated NaCl.
In-situ monitoring
Open-circuit potential (OCP) measured during sliding, alongside the coefficient of friction.
Polarization
Wear under anodic or cathodic polarization to accelerate or suppress corrosion; potentiodynamic polarization and EIS.
Load
Linear tests up to 40 N; rotational tests as a custom configuration, also up to 40 N.
Wear quantification
Wear-track volume from 3D non-contact profilometry after the test.

Why wear and corrosion must be tested together

Many alloys survive corrosive environments only because a thin passive oxide film protects them. Sliding contact scrapes that film away. Fresh metal is exposed, corrodes rapidly until the film reforms, and is then scraped again. Corrosion products and a weakened surface can in turn accelerate mechanical wear. Because of this synergy, a material ranked by a dry wear test and a static corrosion test separately can still fail quickly in tribocorrosion.

The problem is common in biomedical implants sliding in body fluids, in marine and offshore hardware, pumps and valves, and in food, chemical and pharmaceutical processing.

How the module works

The corrosion module is a three-electrode electrochemical cell installed on the tribometer’s sample stage:

  • Working electrode: the sample itself;
  • Counter electrode: a platinum wire;
  • Reference electrode: Ag/AgCl in saturated NaCl.

Wear and corrosion run simultaneously in a ball-on-plate sliding configuration, with the contact fully immersed in the test electrolyte. Linear reciprocating tests run up to 40 N; rotational tests are available as a custom configuration, also up to 40 N.

Reading the signals

Two signals recorded together describe the process:

  • Open-circuit potential (OCP). A drop in OCP at the start of sliding indicates that the protective film has been damaged and active metal is exposed. Recovery after sliding stops shows repassivation.
  • Coefficient of friction. Changes in COF mark the stages of wear development, such as breakthrough of a coating or the build-up of corrosion products in the track.

Correlating OCP with COF shows when protection fails, not just how much material was lost by the end.

Separating mechanical and chemical damage

Tests can also run under controlled potential. Anodic polarization accelerates corrosion and cathodic polarization suppresses it, so comparing wear under each with wear at open circuit separates the contributions of mechanical wear, corrosion and their interaction. ASTM G119 provides a framework for quantifying this wear–corrosion synergism. Potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) characterise the corrosion behaviour of the surface before, during or after sliding.

Measuring the wear

After the test, the wear track is measured by chromatic confocal 3D non-contact profilometry to obtain worn volume. Combined with the electrochemical record, this gives a quantitative account of total material loss under tribocorrosion.

Configurations

Instruments that run this test

Every instrument is built to order. Send us your samples and we run your test in our laboratory first, then configure the instrument around the result.

Published results

Measured in our own laboratory, on the instruments we design and build, and published with full test parameters.

All tribology application notes →

Independent published research

NANOVEA instruments appear in 12 published studies on tribocorrosion and corrosive wear, by researchers at universities and industrial laboratories worldwide.

All 12 studies →

NANOVEA materials testing laboratory

Need tribocorrosion data? Send us your samples.

Our laboratory runs tribocorrosion and immersed wear tests on the same instruments we build, and reports friction, electrochemical data and wear with the full test parameters.

Your samples are tested by the people who design the instruments, so you get advice on the method as well as the numbers.

Friction & wear lab services

Frequently asked questions

What is tribocorrosion?

Degradation of a surface by the combined, simultaneous action of mechanical wear and electrochemical corrosion in a corrosive environment. Wear removes or damages protective passive films and exposes fresh metal that corrodes quickly, while corrosion can weaken the surface and make it wear faster. The total material loss is often greater than wear and corrosion would cause separately.

How does a tribocorrosion test work?

A ball slides on the sample while both are immersed in an electrolyte. The sample is the working electrode of a three-electrode cell, with a platinum wire counter electrode and an Ag/AgCl reference electrode. The open-circuit potential is recorded during sliding, or a potential is imposed, while the friction is measured. Wear volume is measured afterwards by profilometry.

What does the open-circuit potential tell you?

OCP reflects the electrochemical state of the surface. When sliding breaks through a protective passive film or coating, the exposed metal is more active and the OCP shifts to more negative (cathodic) values. A drop in OCP is therefore an indicator of protective-film failure, and its recovery when sliding stops shows how quickly the surface repassivates.

Why run wear tests under anodic or cathodic polarization?

Holding the sample at an anodic potential accelerates corrosion, while a cathodic potential suppresses it. Comparing wear under these conditions with wear at open circuit separates the mechanical and electrochemical contributions to total material loss, the wear–corrosion synergy.

What electrochemical measurements are possible?

Open-circuit potential during sliding, wear at imposed anodic or cathodic potential, potentiodynamic polarization, and electrochemical impedance spectroscopy (EIS), all with the cell connected to a potentiostat.

What materials is tribocorrosion testing used for?

Passive alloys such as stainless steels, titanium and cobalt-chromium used in implants, marine and offshore components, chemical and food processing equipment, and protective coatings such as DLC on steel, wherever surfaces slide in a corrosive liquid.