Tribology testing · Low temperature module

Low Temperature Tribology Testing

The low temperature module encloses the tribological contact and fills it with cold, dry air, so friction and wear tests run at temperatures down to -40 °C. A cryogenic adapter extends rotational and linear tests to -150 °C. Rubbers, polymers, lubricants and coatings can behave very differently below zero, so they need testing at the temperatures they meet in service.

Low temperature enclosure module on a NANOVEA tribometer

At a glance

Temperature
Down to -40 °C in the cold enclosure; to -150 °C with the cryogenic adapter (linear and rotational).
Enclosure
The contact is fully enclosed in a removable chamber, with cold dry air introduced under positive pressure.
Uniformity
The enclosure keeps the temperature uniform and stable around sample and counterbody throughout the test.
Modules
Rotational, linear and scratch.
Measurements
Static and dynamic coefficient of friction, wear behaviour, and wear rate from 3D profilometry after the test.
Typical materials
Tire and seal rubbers, polymers, lubricants and greases, coatings for cold-climate or aerospace use.

Why test below zero

Tires, seals, wiper blades, aircraft components, cold-chain equipment and outdoor machinery all run at sub-zero temperatures. Their materials are usually characterised at room temperature, yet cold changes tribological behaviour substantially. Elastomers stiffen and lose grip; polymers become more brittle; greases and oils thicken; moisture can freeze at the interface. Low temperature tribology measures friction and wear at the temperature the part actually sees.

How the module works

The contact is fully enclosed in a removable chamber. Cold dry air is introduced under positive pressure, which keeps the temperature uniform and stable around the sample and counterbody for the whole test. The enclosure reaches -40 °C. For colder conditions, a cryogenic adapter extends rotational and linear tests down to -150 °C.

Because the chamber surrounds the contact rather than only chilling the stage, the counterbody is at temperature as well as the sample. That matters when the counterbody’s own stiffness or surface film affects the result.

Rubber, speed and temperature

Rubber friction comes mainly from two mechanisms: adhesion at the interface, and energy lost as the rubber deforms over surface asperities. Both depend on how fast the rubber is deformed relative to its viscoelastic response, and that response shifts strongly with temperature. Cooling a rubber has an effect similar to sliding it faster, so friction measured at one temperature cannot simply be transferred to another.

NANOVEA has studied both sides of this: rubber tribology at low temperature, and rubber’s speed-dependent friction at room temperature, where COF against stainless steel rose from 0.29 to 0.8 as speed increased from 0.01 to 5 rpm. For cold-climate applications, testing across both temperature and speed gives the complete picture.

Static and dynamic friction in the cold

Breakaway (static) friction is often what limits a cold mechanism: a seal that sticks, a wiper that chatters, a slide that will not start. The tribometer’s low-speed control lets static and dynamic friction be measured in the enclosure, so stick-slip and breakaway can be compared directly with room-temperature behaviour.

Measuring the wear

After the test, the wear track is measured by chromatic confocal 3D non-contact profilometry, which works on soft and dark materials such as rubber. Worn volume gives the specific wear rate K = V / (F × s) for direct comparison across temperatures.

Tests you can run below zero

Instruments that run this test

Every instrument is built to order. Send us your samples and we run your test in our laboratory first, then configure the instrument around the result.

Published results

Measured in our own laboratory, on the instruments we design and build, and published with full test parameters.

All tribology application notes →

Independent published research

NANOVEA instruments appear in 3 published studies on low-temperature friction and wear, by researchers at universities and industrial laboratories worldwide.

All 3 studies →

NANOVEA materials testing laboratory

Need sub-zero data? Send us your samples.

Our laboratory runs friction and wear tests at low temperature on the same instruments we build, and reports results with the full test parameters and temperature conditions.

Your samples are tested by the people who design the instruments, so you get advice on the method as well as the numbers.

Friction & wear lab services

Frequently asked questions

How cold can a NANOVEA tribometer test?

The low temperature enclosure reaches -40 °C, and a cryogenic adapter takes rotational and linear tests down to -150 °C.

How is the contact kept cold and dry?

The contact is fully enclosed in a removable chamber, and cold dry air is introduced under positive pressure. Keeping the chamber at a slight overpressure of dry air helps keep humid room air out, which limits frost and condensation on the sample during the test.

Why does friction change at low temperature?

Polymers and elastomers stiffen as they cool toward their glass transition, which changes the real contact area and the energy lost by deformation. Lubricants thicken, and surface films can behave differently. For rubber in particular, friction depends strongly on both temperature and sliding speed, so room-temperature data can be misleading for cold-weather tires, seals and wipers.

Can static friction be measured at low temperature?

Yes. Both static and dynamic coefficients of friction can be measured in the enclosure, using the tribometer's low-speed control to capture breakaway behaviour.

Which tests run in the low temperature module?

Rotational (pin-on-disk), linear reciprocating and scratch tests in the cold enclosure; rotational and linear tests with the cryogenic adapter to -150 °C.