Mechanical testing · Humidity module

Humidity-Controlled Nanoindentation

The humidity module encloses the indenter and the sample in a chamber whose relative humidity is controlled from below 5% up to the dew point. Hardness, modulus and creep of moisture-sensitive materials can then be measured at a known, stable humidity rather than whatever the laboratory air happens to be. Many polymers soften markedly as humidity rises.

Humidity chamber enclosing the indenter and sample on a NANOVEA mechanical tester

At a glance

Humidity range
Relative humidity from below 5% up to the dew point.
Enclosure
The chamber encloses both indenter and sample, so they share a uniform controlled environment.
Tests
Nanoindentation hardness and modulus, creep, nanoindentation DMA, scratch and friction.
Analysis
Hardness per ASTM E2546 and the Oliver & Pharr method, as in the published polymer study.
Materials
Polymers and films, biomaterials, natural materials, pharmaceutical and hygroscopic materials.
Platforms
PB1000 and CB500 mechanical testers.

Why humidity matters

Water is a plasticiser for many materials. Nylons, polyurethanes, hydrogels, cellulose films, biological tissues, pharmaceutical tablets and many coatings absorb moisture from the air and become softer and more prone to creep as they do. A hardness measurement at 30% RH and another at 70% RH can describe very different materials. For products used in changing climates, or in the body, mechanical properties need to be known as a function of humidity.

How the module works

A chamber encloses both the indenter and the sample, and the humidity controller sets the relative humidity anywhere from below 5% up to the dew point. Because tip and sample are inside the same uniform environment, the indentation contact itself is at the set humidity. Samples are allowed to equilibrate at each set point before testing, since moisture uptake takes time.

What the data show

In NANOVEA’s humidity-controlled study on a PB1000, a polymer film was indented with a Berkovich tip at 10 mN at 25, 35, 45, 55, 65 and 75% RH, with hardness calculated per ASTM E2546 and the Oliver & Pharr method:

  • from 25% to 55% RH, hardness decreased gradually from about 0.60 to 0.54 GPa, and creep depth rose from 36 to 48 nm;
  • at 65% and 75% RH, hardness dropped to 0.46 and 0.31 GPa, and creep depth climbed to 80 and 105 nm.

The non-linear response, gradual and then rapid, is typical of moisture uptake, and a single room-air measurement would have missed it entirely.

Combining humidity with other tests

Creep, nanoindentation DMA, scratch and low-load friction can all run in the humidity chamber. For friction and wear at controlled humidity under tribological loads, NANOVEA tribometers offer a corresponding humidity and inert-gas module.

Tests you can run at controlled humidity

Instruments that run this test

Every instrument is built to order. Send us your samples and we run your test in our laboratory first, then configure the instrument around the result.

Published results

Measured in our own laboratory, on the instruments we design and build, and published with full test parameters.

All mechanical testing application notes →

Independent published research

NANOVEA instruments appear in 438 published studies on indentation, hardness and scratch, by researchers at universities and industrial laboratories worldwide.

All 438 studies →

NANOVEA materials testing laboratory

Moisture-sensitive material? Send us your samples.

Our laboratory runs humidity-controlled nanoindentation, creep and scratch tests on the same mechanical testers we build, and reports results at each humidity with the full test parameters.

Your samples are tested by the people who design the instruments, so you get advice on the method as well as the numbers.

Indentation & scratch lab services

Frequently asked questions

Why control humidity during nanoindentation?

Many polymers, films and biological materials absorb moisture, which plasticises them: hardness and modulus fall and creep increases. Laboratory humidity varies by day and season, so uncontrolled tests mix material behaviour with weather. Controlling humidity makes results repeatable and lets the moisture effect be measured deliberately.

What humidity range is available?

Relative humidity from below 5% up to the dew point, with the indenter and sample enclosed together in the chamber.

How much can humidity change polymer properties?

Substantially. In NANOVEA's published study, a polymer film's hardness fell from about 0.60 GPa at 25% RH to 0.31 GPa at 75% RH, and creep depth during a 10 s hold nearly tripled, from 36 to 105 nm. The change accelerated above 55% RH.

What are mechano-sorptive effects?

Changes in mechanical behaviour caused by moisture absorption while the material is under load, including accelerated creep. They matter for polymers and natural materials used in changing humidity, such as packaging films, wood and paper products, and medical polymers.

Why must the indenter be inside the chamber too?

So that tip and sample share the same uniform environment. A uniform enclosure avoids local humidity and temperature differences at the contact, which would make the measured properties ambiguous.