Application Note | Large Sample Profilometry
High-Speed Surface Characterization of an Oyster Shell
Patching Multiple Scans to Capture a Large, Curved Biological Sample Without Fixtures

Research & Experimental Testing
Xavier Herrera-Keehn & Jocelyn Esparza
Visual Design & Editorial
Andrew Shore
Introduction
Large samples with complex geometries can prove difficult to work with due to sample preparation, size, sharp angles, and curvature. In this study an oyster shell will be scanned to demonstrate the NANOVEA HS2000 Line Sensor’s capability to scan a large, biological sample with complex geometry. While a biological sample was used in this study, the same concepts can be applied to other samples.
Why 3D Non-Contact Profilometry Matters on an Oyster Shell
By scanning the whole surface of an oyster shell, the NANOVEA HS2000 Line Sensor will display its ability to work with large samples with unique geometries. Typically, samples need to be securely mounted to the stage to mitigate their displacement as the stage moves. This usually requires additional sample preparation or a fixture to be used. But with the smooth air bearing stages on the NANOVEA HS2000, little to no sample preparation is needed to begin your tests.
Patching, shown in this study, allows the NANOVEA HS2000 Line Sensor to capture a surface that has features taller than the optical sensor’s height range or the instrument’s lateral range. This is accomplished by taking multiple scans at varying heights and overlaying them at their relative offsets. And with the stages’ 3 axis motion control, you can index in specified steps in the z direction to quicken the process.
ℹ️ Learn more about non-contact profilometry lab services for large samples.

Measurement Objectives
In this application, an oyster shell was scanned using the NANOVEA HS2000 Line Sensor. Multiple scans were conducted at various heights and reconstructed via patching to represent the whole shell.
Measurement Parameters
| Oyster shell | Value |
|---|---|
| Optical pen | L3 |
| Acquisition rate | 400 pps |
| Averaging | 1 |
| Measured surface | 140 mm × 90 mm |
| Step size | 25 µm × 25 µm |
| Measurement time | 00:05:31 (h:m:s) |
Table 1: Test parameters used for each of the 9 scans performed for this study.

Results
Series of Surfaces
For this study, a total of 9 scans were conducted on the oyster shell to obtain height data over the whole surface. The individual scans are shown in a 3D view below.

3D Surface
The patched 2D and 3D surface can be observed below. We were able to obtain the whole surface of the oyster shell with the NANOVEA HS2000 Line Sensor without compromising on the resolution. Small features on the shell’s surface can still be seen in the 3D view.

Surface Roughness Analysis
Below is the surface roughness of the oyster shell, this was obtained by applying a gaussian filter of 1.5 mm. This excludes form (or waviness) larger than the cut-off index, leaving behind features that represent the oyster shell’s roughness. Despite the lack of a fixture, stage noise was not observed in the surface roughness analysis.

| ISO 25178 parameter | Whole surface (Fig. 2) | Roughness (Fig. 3) |
|---|---|---|
| Sa | 5.054 mm | 0.1255 mm |
| Sq | 6.058 mm | 0.2614 mm |
| Sp | 17.52 mm | 3.987 mm |
| Sv | 12.38 mm | 1.211 mm |
| Sz | 29.90 mm | 5.198 mm |
| Ssk | 0.02877 | 3.737 |
| Sku | 2.281 | 41.93 |
Table 2: Height parameters of the patched surface and of its roughness.
Conclusion
A total of 9 scans were used in this study to recreate the surface of the oyster shell using the NANOVEA HS2000 Line Sensor. From the patched surface, the roughness of the oyster shell was measured by removing the form (or waviness) of the sample. Patching can also be used to measure much finer roughnesses on a large sample that would normally be beyond the optical sensor’s height range. Large conical lenses, for example, require a very fine step size in order to quantify microscopic features that can be present. The NANOVEA HS2000 Line Sensor has shown it is able to conduct profilometry measurements on large samples with abnormal geometries while retaining high resolution with minimal sample preparation.

Frequently Asked Questions About Scanning Large, Complex Samples
What makes large, curved samples difficult to profile?
Sample preparation, size, sharp angles and curvature. Samples usually need secure mounting so they do not move with the stage, which can require extra preparation or a fixture.
What is patching in profilometry?
Patching captures a surface with features taller than the optical sensor’s height range or wider than the lateral range by taking multiple scans at different heights and overlaying them at their relative offsets. Indexing in set Z steps speeds this up.
How was the oyster shell scanned?
Nine scans with the L3 optical pen at 400 pps and a 25 µm × 25 µm step, each over 140 mm × 90 mm in 5 minutes 31 seconds, were patched to reconstruct the whole shell.
Does the sample need a fixture?
Little to no preparation was needed: the HS2000’s smooth air-bearing stages kept the unfixed shell steady, and no stage noise appeared in the roughness analysis.
How is roughness separated from the shell’s shape?
A 1.5 mm Gaussian filter removes form and waviness larger than the cut-off. The whole surface measured Sa 5.054 mm, while the roughness after filtering was Sa 0.1255 mm.
Where else is patching useful?
Patching can measure much finer roughness on large samples beyond the sensor’s height range, for example large conical lenses that need a very fine step to quantify microscopic features.



