<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Notas de aplicación sobre tribología líquida - NANOVEA: perfilómetros, tribómetros, nanoindentadores y medidores de rayaduras avanzados para el ensayo de materiales.</title>
	<atom:link href="https://nanovea.com/es/category/application-notes/tribology-testing/liquid-tribology/feed/" rel="self" type="application/rss+xml" />
	<link>https://nanovea.com/es/categoria/notas-de-aplicacion-2/pruebas-de-tribologia/liquido-tribologia/</link>
	<description>Instrumentos de metrología para la investigación de materiales y el control de calidad</description>
	<lastbuilddate>Fri, 07 Nov 2025 00:22:44 +0000</lastbuilddate>
	<language>es</language>
	<sy:updateperiod>
	hourly	</sy:updateperiod>
	<sy:updatefrequency>
	1	</sy:updatefrequency>
	<generator>https://wordpress.org/?v=6.8.5</generator>

<image>
	<url>https://nanovea.com/wp-content/uploads/2025/02/nanovea-favicon.png</url>
	<title>Notas de aplicación sobre tribología líquida - NANOVEA: perfilómetros, tribómetros, nanoindentadores y medidores de rayaduras avanzados para el ensayo de materiales.</title>
	<link>https://nanovea.com/es/categoria/notas-de-aplicacion-2/pruebas-de-tribologia/liquido-tribologia/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Rendimiento de abrasión con papel de lija utilizando un tribómetro</title>
		<link>https://nanovea.com/es/papel-de-lija-abrasion-rendimiento-usando-un-tribometro/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=sandpaper-abrasion-performance-using-a-tribometer</link>
					<comments>https://nanovea.com/es/papel-de-lija-abrasion-rendimiento-usando-un-tribometro/#respond</comments>
		
		<dc:creator><![CDATA[nanovea]]></dc:creator>
		<pubdate>Mon, 01 Nov 2021 20:39:55 +0000</pubdate>
				<category><![CDATA[Application Notes]]></category>
		<category><![CDATA[Laboratory Testing]]></category>
		<category><![CDATA[Liquid Tribology]]></category>
		<category><![CDATA[Profilometry | Volume and Area]]></category>
		<category><![CDATA[Profilometry Testing]]></category>
		<category><![CDATA[Rotational Tribology]]></category>
		<category><![CDATA[Tribology Testing]]></category>
		<guid ispermalink="false">https://nanovea.com/?p=16045</guid>

					<description><![CDATA[<p>SANDPAPER ABRASION PERFORMANCE USING A TRIBOMETER Prepared by DUANJIE LI, PhD INTRODUCTION Sandpaper consists of abrasive particles glued to one face of a paper or cloth. Various abrasive materials can be used for the particles, such as garnet, silicon carbide, aluminum oxide and diamond. Sandpaper is widely applied in a variety of industrial sectors to [&#8230;]</p>
<p>The post <a href="https://nanovea.com/es/papel-de-lija-abrasion-rendimiento-usando-un-tribometro/">Sandpaper Abrasion Performance Using a Tribometer</a> appeared first on <a href="https://nanovea.com/es">NANOVEA: Advanced Profilometers, Tribometers, Nanoindenters, and Scratch Testers for Materials Testing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div data-elementor-type="wp-post" data-elementor-id="16045" class="elementor elementor-16045" data-elementor-post-type="post">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-7ec3d48 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="7ec3d48" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c477953" data-id="c477953" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-366d50f elementor-widget elementor-widget-heading" data-id="366d50f" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h1 class="elementor-heading-title elementor-size-default">RENDIMIENTO DE ABRASIÓN DEL PAPEL DE LAMA</h1>				</div>
				</div>
				<div class="elementor-element elementor-element-d107f9b elementor-widget elementor-widget-heading" data-id="d107f9b" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">UTILIZANDO UN TRIBÓMETRO</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-73c118d elementor-widget elementor-widget-image" data-id="73c118d" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img fetchpriority="high" decoding="async" width="768" height="217" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Abrasion-Testing-Services.jpg" class="attachment-medium_large size-medium_large wp-image-16071" alt="prueba de abrasión con lija" />															</div>
				</div>
				<div class="elementor-element elementor-element-97cc106 elementor-widget elementor-widget-heading" data-id="97cc106" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">Preparado por</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-95aa94e elementor-widget elementor-widget-heading" data-id="95aa94e" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">DUANJIE LI, Doctor</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-c14383d elementor-widget elementor-widget-spacer" data-id="c14383d" data-element_type="widget" data-widget_type="spacer.default">
				<div class="elementor-widget-container">
							<div class="elementor-spacer">
			<div class="elementor-spacer-inner"></div>
		</div>
						</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-753c1f3 elementor-section-content-middle elementor-reverse-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="753c1f3" data-element_type="section" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-f2074e4 elementor-hidden-phone" data-id="f2074e4" data-element_type="column" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
			<div class="elementor-widget-wrap">
							</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-b259d86" data-id="b259d86" data-element_type="column" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-62f2a44 elementor-widget elementor-widget-heading" data-id="62f2a44" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">INTRODUCCIÓN</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-9ab0009 elementor-widget elementor-widget-text-editor" data-id="9ab0009" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>El papel de lija está compuesto por partículas abrasivas adheridas a una de las caras de un papel o tela. Para las partículas se pueden utilizar diversos materiales abrasivos, como granate, carburo de silicio, óxido de aluminio y diamante. El papel de lija se utiliza ampliamente en diversos sectores industriales para crear acabados superficiales específicos en madera, metal y paneles de yeso. A menudo se trabaja con él aplicando una gran presión con la mano o con herramientas eléctricas.</p>								</div>
				</div>
				<div class="elementor-element elementor-element-c9a07fb elementor-widget elementor-widget-heading" data-id="c9a07fb" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">IMPORTANCIA DE EVALUAR EL RENDIMIENTO DE LA ABRASIÓN DEL PAPEL DE LIMA</h3>				</div>
				</div>
				<div class="elementor-element elementor-element-e74abb9 elementor-widget elementor-widget-text-editor" data-id="e74abb9" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>La eficacia del papel de lija suele determinarse por su rendimiento abrasivo en diferentes condiciones. El tamaño del grano, es decir, el tamaño de las partículas abrasivas incrustadas en el papel de lija, determina la tasa de desgaste y el tamaño de los rayones del material que se lija. Los papeles de lija con números de grano más altos tienen partículas más pequeñas, lo que da como resultado velocidades de lijado más bajas y acabados superficiales más finos. Los papeles de lija con el mismo número de grano pero fabricados con materiales diferentes pueden tener comportamientos distintos en condiciones secas o húmedas. Se necesitan evaluaciones tribológicas fiables para garantizar que el papel de lija fabricado posea el comportamiento abrasivo deseado. Estas evaluaciones permiten a los usuarios comparar cuantitativamente los comportamientos de desgaste de diferentes tipos de papeles de lija de forma controlada y supervisada, con el fin de seleccionar el mejor candidato para la aplicación deseada.</p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-bbe0c25 elementor-reverse-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="bbe0c25" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-5bda47b" data-id="5bda47b" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<section class="elementor-section elementor-inner-section elementor-element elementor-element-702ad1d elementor-reverse-mobile elementor-section-full_width elementor-reverse-tablet elementor-section-height-default elementor-section-height-default" data-id="702ad1d" data-element_type="section">
						<div class="elementor-container elementor-column-gap-no">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-9623762" data-id="9623762" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-267c2d8 elementor-widget elementor-widget-heading" data-id="267c2d8" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">OBJETIVO DE MEDICIÓN</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-fa7ad49 elementor-widget elementor-widget-text-editor" data-id="fa7ad49" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><em>En este estudio, mostramos la capacidad del tribómetro neumático de alta carga NANOVEA T2000 para evaluar cuantitativamente el rendimiento de abrasión de varias muestras de papel de lija en condiciones secas y húmedas.</em></p>								</div>
				</div>
				<div class="elementor-element elementor-element-0efde9a elementor-widget__width-initial elementor-widget elementor-widget-text-editor" data-id="0efde9a" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center; font-size: 20pt; color: black;">NANOVEA <span style="font-size: 20pt; color: #1b96cf;">T2000 Alta carga<br /></span><span style="font-size: 20pt;">Tribómetro neumático</span></p>								</div>
				</div>
		<div class="elementor-element elementor-element-29a08fb e-grid e-con-full e-con e-child" data-id="29a08fb" data-element_type="container">
				<div class="elementor-element elementor-element-4f88fcd elementor-align-center homepage-button-brochure elementor-widget elementor-widget-button" data-id="4f88fcd" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
									<div class="elementor-button-wrapper">
					<a class="elementor-button elementor-button-link elementor-size-sm" href="https://nanovea.com/t2000-tribometer-brochure-form/" id="homepage-button-brochure">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">DESCARGAR FOLLETO</span>
					</span>
					</a>
				</div>
								</div>
				</div>
				<div class="elementor-element elementor-element-c967855 elementor-align-center homepage-button-quote elementor-widget elementor-widget-button" data-id="c967855" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
									<div class="elementor-button-wrapper">
					<a class="elementor-button elementor-button-link elementor-size-sm" href="https://nanovea.com/contact-sales-form/" id="homepage-button-quote">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">SOLICITAR PRESUPUESTO</span>
					</span>
					</a>
				</div>
								</div>
				</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c441b48" data-id="c441b48" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-7e3594e elementor-widget elementor-widget-image" data-id="7e3594e" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
																<a href="https://nanovea.com/instruments/t2000/">
							<img decoding="async" width="591" height="579" src="https://nanovea.com/wp-content/uploads/2022/06/NANOVEA-Tribometer-T2000.png" class="elementor-animation-grow attachment-medium_large size-medium_large wp-image-20089" alt="Tribómetro neumático de alta carga NANOVEA T2000" />								</a>
															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-e767880 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="e767880" data-element_type="section">
						<div class="elementor-container elementor-column-gap-no">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-da0379b" data-id="da0379b" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-b8511cd elementor-widget elementor-widget-heading" data-id="b8511cd" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">PROCEDIMIENTOS DE PRUEBA</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-3c63d98 elementor-widget elementor-widget-text-editor" data-id="3c63d98" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>El coeficiente de fricción (COF) y el rendimiento de abrasión de dos tipos de papeles de lija se evaluaron con el tribómetro NANOVEA T100. Se utilizó una bola de acero inoxidable 440 como material de contrapartida. Las marcas de desgaste de la bola se examinaron después de cada prueba de desgaste utilizando el NANOVEA. <a href="https://nanovea.com/profilometers/">Perfilador óptico 3D sin contacto</a> para garantizar mediciones precisas de la pérdida de volumen.</p><p>Tenga en cuenta que se eligió una bola de acero inoxidable 440 como material de contrapartida para realizar un estudio comparativo, pero se podría sustituir por cualquier material sólido para simular una condición de aplicación diferente.</p>								</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-b45cc31 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="b45cc31" data-element_type="section">
						<div class="elementor-container elementor-column-gap-no">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-0b0b9cc" data-id="0b0b9cc" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-2752b9e elementor-widget elementor-widget-image" data-id="2752b9e" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img decoding="async" width="892" height="501" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Abrasion-Test-Parameters.jpg" class="attachment-large size-large wp-image-16033" alt="Parámetros de prueba de abrasión con lija" />															</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-dfbb12c elementor-hidden-mobile" data-id="dfbb12c" data-element_type="column" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-aed1bc3 elementor-widget elementor-widget-image" data-id="aed1bc3" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="758" height="513" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Abrasion-Weat-Test.jpg" class="attachment-large size-large wp-image-16034" alt="pruebas tribológicas con lija" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-1979bac elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="1979bac" data-element_type="section">
						<div class="elementor-container elementor-column-gap-no">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c969083" data-id="c969083" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-9c67049 elementor-widget elementor-widget-heading" data-id="9c67049" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">RESULTADOS DE LAS PRUEBAS Y DISCUSIÓN</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-4c14a59 elementor-widget elementor-widget-text-editor" data-id="4c14a59" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>La FIGURA 1 muestra una comparación del COF del papel de lija 1 y 2 en condiciones ambientales secas y húmedas. El papel de lija 1, en condiciones secas, muestra un COF de 0,4 al inicio de la prueba, que disminuye progresivamente y se estabiliza en 0,3. En condiciones húmedas, esta muestra presenta un COF medio más bajo, de 0,27. Por el contrario, los resultados del COF de la muestra 2 muestran un COF seco de 0,27 y un COF húmedo de ~ 0,37. </p><p>Tenga en cuenta que la oscilación en los datos de todos los gráficos COF se debió a las vibraciones generadas por el movimiento deslizante de la bola contra las superficies rugosas del papel de lija.</p>								</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-f6f1994 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f6f1994" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-64b2fd4" data-id="64b2fd4" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-7d4ccd8 elementor-widget elementor-widget-image" data-id="7d4ccd8" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="634" height="508" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Abrasion-COF.jpg" class="attachment-large size-large wp-image-16030" alt="Coeficiente de fricción por abrasión con lija" />															</div>
				</div>
				<div class="elementor-element elementor-element-9be55a4 elementor-widget elementor-widget-text-editor" data-id="9be55a4" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 1: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;"><span class="fontstyle0">Evolución del COF durante las pruebas de desgaste.</span> <br /></span></span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-99b5f0a elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="99b5f0a" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-936bcc6" data-id="936bcc6" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-2571aa5 elementor-widget elementor-widget-text-editor" data-id="2571aa5" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>La FIGURA 2 resume los resultados del análisis de las marcas de desgaste. Las marcas de desgaste se midieron utilizando un microscopio óptico y un perfilómetro óptico sin contacto NANOVEA 3D. Las FIGURAS 3 y 4 comparan las marcas de desgaste de las bolas SS440 desgastadas tras las pruebas de desgaste en el papel de lija 1 y 2 (en condiciones húmedas y secas). Como se muestra en la FIGURA 4, el perfilómetro óptico NANOVEA captura con precisión la topografía de la superficie de las cuatro bolas y sus respectivas marcas de desgaste, que luego se procesaron con el software de análisis avanzado NANOVEA Mountains para calcular la pérdida de volumen y la tasa de desgaste. En la imagen microscópica y del perfil de la bola se puede observar que la bola utilizada para la prueba con lija 1 (seca) presentaba una marca de desgaste aplanada más grande en comparación con las demás, con una pérdida de volumen de 0,313. <span style="color: #202124; font-family: Roboto, arial, sans-serif; font-size: 16px; text-align: left;">mm</span><sup style="color: #202124; font-family: Roboto, arial, sans-serif; text-align: left;">3</sup>. Por el contrario, la pérdida de volumen del papel de lija 1 (húmedo) fue de 0,131. <span style="color: #202124; font-family: Roboto, arial, sans-serif; font-size: 16px; text-align: left;">mm</span><sup style="color: #202124; font-family: Roboto, arial, sans-serif; text-align: left;">3</sup>. Para el papel de lija 2 (seco), la pérdida de volumen fue de 0,163. <span style="color: #202124; font-family: Roboto, arial, sans-serif; font-size: 16px; text-align: left;">mm</span><sup style="color: #202124; font-family: Roboto, arial, sans-serif; text-align: left;">3</sup> y para el papel de lija 2 (húmedo), la pérdida de volumen aumentó a 0,237. <span style="color: #202124; font-family: Roboto, arial, sans-serif; font-size: 16px; text-align: left;">mm</span><sup style="color: #202124; font-family: Roboto, arial, sans-serif; text-align: left;">3</sup>.</p><p>Además, es interesante observar que el COF desempeñó un papel importante en el rendimiento de abrasión de las lijas. La lija 1 presentó un COF más alto en condiciones secas, lo que dio lugar a una mayor tasa de abrasión para la bola SS440 utilizada en la prueba. En comparación, el mayor COF del papel de lija 2 en condiciones húmedas dio lugar a una mayor tasa de abrasión. Las marcas de desgaste de los papeles de lija después de las mediciones se muestran en la FIGURA 5.</p>								</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-5243fdc elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="5243fdc" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-7b65061" data-id="7b65061" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-0834b45 elementor-widget elementor-widget-text-editor" data-id="0834b45" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>Tanto el papel de lija 1 como el 2 afirman funcionar tanto en entornos secos como húmedos. Sin embargo, mostraron un rendimiento de abrasión significativamente diferente en condiciones secas y húmedas. NANOVEA <a href="https://nanovea.com/tribometers/">tribómetros </a>proporcionan capacidades de evaluación del desgaste cuantificables, fiables y bien controladas que garantizan evaluaciones reproducibles del desgaste. Además, la capacidad de medición del COF in situ permite a los usuarios correlacionar las diferentes etapas de un proceso de desgaste con la evolución del COF, lo cual es fundamental para mejorar la comprensión básica del mecanismo de desgaste y las características tribológicas del papel de lija.</p>								</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-2c86b20" data-id="2c86b20" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-b124e96 elementor-widget elementor-widget-image" data-id="b124e96" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="507" height="348" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Abrasion-Tribometer.jpg" class="attachment-large size-large wp-image-16029" alt="prueba de tribología por abrasión con lija" />															</div>
				</div>
				<div class="elementor-element elementor-element-1cb2f3a elementor-widget elementor-widget-text-editor" data-id="1cb2f3a" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 2: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;"><span class="fontstyle0">Desgaste del volumen de las bolas y COF promedio en diferentes condiciones.</span><br /></span></span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-fa6741e elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="fa6741e" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9b17f53" data-id="9b17f53" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<section class="elementor-section elementor-inner-section elementor-element elementor-element-12f15ce elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="12f15ce" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-9bfb322" data-id="9bfb322" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-6579947 elementor-widget elementor-widget-image" data-id="6579947" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="473" height="439" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Abrasion-Dry-Wear-Test-1.jpg" class="attachment-large size-large wp-image-16031" alt="prueba de abrasión con lija - en seco" />															</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-d116436" data-id="d116436" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-32121fc elementor-widget elementor-widget-image" data-id="32121fc" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="474" height="439" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Abrasion-Dry-Wear-Test-2.jpg" class="attachment-large size-large wp-image-16032" alt="Prueba de abrasión con lija - en seco" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-5949d99 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="5949d99" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-95d1eab" data-id="95d1eab" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-924abcb elementor-widget elementor-widget-image" data-id="924abcb" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="473" height="440" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Abrasion-Wet-Wear-Test-1.jpg" class="attachment-large size-large wp-image-16035" alt="prueba de abrasión con lija - húmeda" />															</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-0b47d21" data-id="0b47d21" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-a34cfe7 elementor-widget elementor-widget-image" data-id="a34cfe7" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="474" height="440" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Abrasion-Wet-Wear-Test-2.jpg" class="attachment-large size-large wp-image-16036" alt="Prueba de abrasión con lija - húmeda" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<div class="elementor-element elementor-element-60a7a04 elementor-widget elementor-widget-text-editor" data-id="60a7a04" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 3: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;"><span class="fontstyle0">Lleva las cicatrices de las pelotas después de las pruebas.</span><br /></span></span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-c34553d elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="c34553d" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7cf53e9" data-id="7cf53e9" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<section class="elementor-section elementor-inner-section elementor-element elementor-element-6de26da elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="6de26da" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-1fbbe81" data-id="1fbbe81" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-ab1e89b elementor-widget elementor-widget-image" data-id="ab1e89b" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="615" height="445" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Dry-Profilometer-1.jpg" class="attachment-large size-large wp-image-16037" alt="abrasión con lija - perfilometría" />															</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-7bc2599" data-id="7bc2599" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-4e44f33 elementor-widget elementor-widget-image" data-id="4e44f33" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="615" height="445" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Dry-Profilometer-2.jpg" class="attachment-large size-large wp-image-16038" alt="abrasión con lija - perfil de la superficie" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-cd6b5bf elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="cd6b5bf" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-f12cb8e" data-id="f12cb8e" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-7d7f928 elementor-widget elementor-widget-image" data-id="7d7f928" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="615" height="445" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Wet-Profilometer-1.jpg" class="attachment-large size-large wp-image-16043" alt="Prueba de abrasión con lija - Perfil tridimensional de la superficie" />															</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-9de0742" data-id="9de0742" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-0f391dd elementor-widget elementor-widget-image" data-id="0f391dd" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="615" height="445" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Wet-Profilometer-2.jpg" class="attachment-large size-large wp-image-16044" alt="Prueba de abrasión con lija - Escaneo 3D de superficies" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<div class="elementor-element elementor-element-dabaf49 elementor-widget elementor-widget-text-editor" data-id="dabaf49" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 4: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;"><span class="fontstyle0">Morfología 3D de las marcas de desgaste en las bolas.</span><br /></span></span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-d910ad4 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="d910ad4" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f639602" data-id="f639602" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<section class="elementor-section elementor-inner-section elementor-element elementor-element-45d22ed elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="45d22ed" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-55650fc" data-id="55650fc" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-e1b6f1e elementor-widget elementor-widget-image" data-id="e1b6f1e" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="512" height="469" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Wear-Test-Dry-1.jpg" class="attachment-large size-large wp-image-16039" alt="Resultados de la prueba de abrasión con lija" />															</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-74b8658" data-id="74b8658" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-06caf52 elementor-widget elementor-widget-image" data-id="06caf52" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="511" height="469" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Wear-Test-Dry-2.jpg" class="attachment-large size-large wp-image-16040" alt="Resultados de las pruebas de abrasión con lija" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-08577af elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="08577af" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-566bb8b" data-id="566bb8b" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-19f02a8 elementor-widget elementor-widget-image" data-id="19f02a8" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="512" height="469" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Wear-Test-Wet-1.jpg" class="attachment-large size-large wp-image-16041" alt="Resultados de la prueba tribológica de abrasión con lija" />															</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-507e7a3" data-id="507e7a3" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-b0dbabf elementor-widget elementor-widget-image" data-id="b0dbabf" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="511" height="468" src="https://nanovea.com/wp-content/uploads/2021/10/Sandpaper-Wear-Test-Wet-2.jpg" class="attachment-large size-large wp-image-16042" alt="Resultados de las pruebas de abrasión con lija" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<div class="elementor-element elementor-element-db6c287 elementor-widget elementor-widget-text-editor" data-id="db6c287" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 5: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;"><span class="fontstyle0">Desgaste de las bandas de rodadura en los papeles de lija en diferentes condiciones.</span><br /></span></span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-9c9a5b1 elementor-section-content-middle elementor-reverse-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="9c9a5b1" data-element_type="section" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-f2d1204 elementor-hidden-phone" data-id="f2d1204" data-element_type="column" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
			<div class="elementor-widget-wrap">
							</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-3f87574" data-id="3f87574" data-element_type="column" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-8843a9f elementor-widget elementor-widget-heading" data-id="8843a9f" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">CONCLUSIÓN</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-18f7f2e elementor-widget elementor-widget-text-editor" data-id="18f7f2e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>En este estudio se evaluó el rendimiento de abrasión de dos tipos de lijas con el mismo número de grano en condiciones secas y húmedas. Las condiciones de uso de la lija desempeñan un papel fundamental en la eficacia del rendimiento del trabajo. La lija 1 presentó un comportamiento de abrasión significativamente mejor en condiciones secas, mientras que la lija 2 obtuvo mejores resultados en condiciones húmedas. La fricción durante el proceso de lijado es un factor importante a tener en cuenta a la hora de evaluar el rendimiento de abrasión. El perfilómetro óptico NANOVEA mide con precisión la morfología 3D de cualquier superficie, como las marcas de desgaste en una bola, lo que garantiza una evaluación fiable del rendimiento de abrasión del papel de lija en este estudio. El tribómetro NANOVEA mide el coeficiente de fricción in situ durante una prueba de desgaste, lo que proporciona información sobre las diferentes etapas de un proceso de desgaste. También ofrece pruebas de desgaste y fricción repetibles utilizando modos rotativos y lineales que cumplen con las normas ISO y ASTM, con módulos opcionales de desgaste a alta temperatura y lubricación disponibles en un sistema preintegrado. Esta gama inigualable permite a los usuarios simular diferentes entornos de trabajo severos de los rodamientos de bolas, incluyendo altas tensiones, desgaste y altas temperaturas, etc. También proporciona una herramienta ideal para evaluar cuantitativamente los comportamientos tribológicos de materiales superiores resistentes al desgaste bajo cargas elevadas.</p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-f8f5f67 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f8f5f67" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a8891e3" data-id="a8891e3" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-0ef778b elementor-widget elementor-widget-heading" data-id="0ef778b" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">¿Tiene una aplicación similar?</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-07a7a14 elementor-align-justify open-chat elementor-widget elementor-widget-button" data-id="07a7a14" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
									<div class="elementor-button-wrapper">
					<a class="elementor-button elementor-size-sm" role="button">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">HABLE AHORA CON UN EXPERTO</span>
					</span>
					</a>
				</div>
								</div>
				</div>
				<div class="elementor-element elementor-element-5818d0a elementor-align-justify button-quote elementor-widget elementor-widget-button" data-id="5818d0a" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
									<div class="elementor-button-wrapper">
					<a class="elementor-button elementor-button-link elementor-size-sm" href="https://nanovea.com/contact-sales-form/" id="button-quote-bottom">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">OBTENGA PRECIOS Y DETALLES RÁPIDAMENTE</span>
					</span>
					</a>
				</div>
								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div><p>The post <a href="https://nanovea.com/es/papel-de-lija-abrasion-rendimiento-usando-un-tribometro/">Sandpaper Abrasion Performance Using a Tribometer</a> appeared first on <a href="https://nanovea.com/es">NANOVEA: Advanced Profilometers, Tribometers, Nanoindenters, and Scratch Testers for Materials Testing</a>.</p>
]]></content:encoded>
					
					<wfw:commentrss>https://nanovea.com/es/papel-de-lija-abrasion-rendimiento-usando-un-tribometro/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pruebas de desgaste del pistón</title>
		<link>https://nanovea.com/es/prueba-de-desgaste-del-piston/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=piston-wear-testing</link>
					<comments>https://nanovea.com/es/prueba-de-desgaste-del-piston/#respond</comments>
		
		<dc:creator><![CDATA[nanovea]]></dc:creator>
		<pubdate>Tue, 21 Sep 2021 20:41:22 +0000</pubdate>
				<category><![CDATA[Application Notes]]></category>
		<category><![CDATA[Laboratory Testing]]></category>
		<category><![CDATA[Linear Tribology]]></category>
		<category><![CDATA[Liquid Tribology]]></category>
		<category><![CDATA[Profilometry | Volume and Area]]></category>
		<category><![CDATA[Profilometry Testing]]></category>
		<category><![CDATA[Tribology Testing]]></category>
		<guid ispermalink="false">https://nanovea.com/?p=15548</guid>

					<description><![CDATA[<p>PISTON WEAR TESTINGUSING NANOVEA TRIBOMETER Prepared by FRANK LIU What Is Piston Wear Testing? Piston wear testing evaluates the friction, lubrication, and material durability between piston skirts and cylinder liners under controlled laboratory conditions. Using a tribometer, engineers can replicate real reciprocating motion and precisely measure the coefficient of friction, wear rate, and 3D surface [&#8230;]</p>
<p>The post <a href="https://nanovea.com/es/prueba-de-desgaste-del-piston/">Piston Wear Testing</a> appeared first on <a href="https://nanovea.com/es">NANOVEA: Advanced Profilometers, Tribometers, Nanoindenters, and Scratch Testers for Materials Testing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div data-elementor-type="wp-post" data-elementor-id="15548" class="elementor elementor-15548" data-elementor-post-type="post">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-7ec3d48 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="7ec3d48" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c477953" data-id="c477953" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-6cd685c elementor-widget elementor-widget-text-editor" data-id="6cd685c" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<h1 style="text-align: center; font-style: italic; font-weight: bold;"><span style="font-size: 62px; color: #1b96cf; display: block;">PRUEBAS DE DESGASTE DE PISTONES</span><span style="font-size: 32px; color: #000;">UTILIZANDO EL TRIBÓMETRO NANOVEA</span></h1>								</div>
				</div>
				<div class="elementor-element elementor-element-73c118d elementor-widget elementor-widget-image" data-id="73c118d" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="768" height="217" src="https://nanovea.com/wp-content/uploads/2021/09/piston-wear-testing-tribometer-nanovea.jpg" class="attachment-medium_large size-medium_large wp-image-25200" alt="Pruebas de desgaste del pistón utilizando el tribómetro NANOVEA en condiciones lubricadas." />															</div>
				</div>
				<div class="elementor-element elementor-element-97cc106 elementor-widget elementor-widget-heading" data-id="97cc106" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">Preparado por</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-95aa94e elementor-widget elementor-widget-heading" data-id="95aa94e" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">FRANK LIU</h2>				</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-753c1f3 elementor-section-content-middle elementor-reverse-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="753c1f3" data-element_type="section" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-f2074e4" data-id="f2074e4" data-element_type="column" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-c53ea2a elementor-widget elementor-widget-spacer" data-id="c53ea2a" data-element_type="widget" data-widget_type="spacer.default">
				<div class="elementor-widget-container">
							<div class="elementor-spacer">
			<div class="elementor-spacer-inner"></div>
		</div>
						</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-b259d86" data-id="b259d86" data-element_type="column" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-62f2a44 elementor-widget elementor-widget-heading" data-id="62f2a44" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">¿Qué es la prueba de desgaste de pistones?</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-9ab0009 elementor-widget elementor-widget-text-editor" data-id="9ab0009" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: justify;">Las pruebas de desgaste de pistones evalúan la fricción, la lubricación y la durabilidad de los materiales entre las faldas de pistón y las camisas de cilindro en condiciones controladas de laboratorio. Utilizando un <a href="https://nanovea.com/tribometers/">tribómetro</a>Los ingenieros pueden reproducir el movimiento alternativo real y medir con precisión el coeficiente de fricción, la tasa de desgaste y la topografía de la superficie en 3D. Estos resultados proporcionan información clave sobre el comportamiento tribológico de los revestimientos, lubricantes y aleaciones utilizados en los pistones de los motores, ayudando a optimizar el rendimiento, la eficiencia del combustible y la fiabilidad a largo plazo.</p>								</div>
				</div>
				<div class="elementor-element elementor-element-97afdf1 elementor-widget elementor-widget-image" data-id="97afdf1" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="583" height="254" src="https://nanovea.com/wp-content/uploads/2021/09/piston-liner-lubricant-interface-schematic-nanovea.png" class="attachment-large size-large wp-image-25174" alt="esquema de la interfaz de lubricación de la falda del pistón y la camisa del cilindro durante las pruebas de desgaste" />															</div>
				</div>
				<div class="elementor-element elementor-element-aa685ab elementor-widget elementor-widget-text-editor" data-id="aa685ab" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p> <span class="fontstyle0">Esquema del sistema de cilindros de potencia e interfaces falda del pistón-lubricante-guarnición del cilindro.</span> </p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-8be3d94 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="8be3d94" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-70feb6a" data-id="70feb6a" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-0d73b67 elementor-widget elementor-widget-text-editor" data-id="0d73b67" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>💡<em data-start="1410" data-end="1468"> ¿Desea cuantificar la tasa de desgaste y la fricción de sus propias muestras? <a href="https://nanovea.com/contact-lab-form/">Solicite una prueba tribológica personalizada adaptada a su aplicación.</a></em></p>								</div>
				</div>
				<div class="elementor-element elementor-element-4c97d3d elementor-widget elementor-widget-heading" data-id="4c97d3d" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">Por qué son importantes las pruebas de desgaste del pistón en el desarrollo de motores</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-b5ef8e5 elementor-widget elementor-widget-text-editor" data-id="b5ef8e5" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span class="fontstyle0">El aceite de motor es un lubricante bien diseñado para su aplicación. Además del aceite base, se añaden aditivos como detergentes, dispersantes, mejoradores de la viscosidad (VI), agentes antidesgaste/antifricción e inhibidores de la corrosión para mejorar su rendimiento. Estos aditivos afectan al comportamiento del aceite en diferentes condiciones de funcionamiento. El comportamiento del aceite afecta a las interfaces P-L-C y determina si se produce un desgaste significativo por contacto metal-metal o si se produce lubricación hidrodinámica (muy poco desgaste).</span></p><p><span class="fontstyle0">Es difícil comprender las interfaces P-L-C sin aislar la zona de las variables externas. Resulta más práctico simular el suceso con condiciones representativas de su aplicación en la vida real. El sitio </span><span class="fontstyle2">NANOVEA </span><span class="fontstyle0">Tribometer es ideal para ello. Equipado con múltiples sensores de fuerza, sensor de profundidad, un módulo de lubricante gota a gota y una etapa lineal alternativa, el </span><a href="https://nanovea.com/instruments/t2000/"><span class="fontstyle2">NANOVEA </span></a><span class="fontstyle0"><a href="https://nanovea.com/instruments/t2000/">T2000</a> es capaz de imitar de cerca los acontecimientos que se producen en el interior de un bloque motor y obtener datos valiosos para comprender mejor las interfaces P-L-C.</span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-8c0270e elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="8c0270e" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-85ba117" data-id="85ba117" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-cc22aae elementor-widget elementor-widget-image" data-id="cc22aae" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="694" height="390" src="https://nanovea.com/wp-content/uploads/2021/09/piston-wear-friction-testing-module-nanovea.jpg" class="attachment-large size-large wp-image-25173" alt="nanovea tribometer piston wear and friction testing module setup" />															</div>
				</div>
				<div class="elementor-element elementor-element-013f49e elementor-widget elementor-widget-text-editor" data-id="013f49e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;">Módulo de líquido en el tribómetro NANOVEA T2000</p>								</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-3fd5de6" data-id="3fd5de6" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-894a3bf elementor-widget elementor-widget-text-editor" data-id="894a3bf" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span class="fontstyle0">El módulo gota a gota es crucial para este estudio. Dado que los pistones pueden moverse a gran velocidad (más de 3.000 rpm), es difícil crear una fina película de lubricante sumergiendo la muestra. Para solucionar este problema, el módulo gota a gota es capaz de aplicar una cantidad constante de lubricante sobre la superficie de la falda del pistón.</span></p><p><span class="fontstyle0">La aplicación de lubricante fresco también elimina la preocupación de que los contaminantes de desgaste desalojados influyan en las propiedades del lubricante.</span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-58f9047 elementor-reverse-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="58f9047" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a77506d" data-id="a77506d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-3bf4598 elementor-widget elementor-widget-heading" data-id="3bf4598" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">Cómo simulan los tribómetros <br> Desgaste real de la camisa del pistón</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-1cad070 elementor-widget elementor-widget-text-editor" data-id="1cad070" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>En este informe se estudiarán las interfaces falda del pistón-lubricante- camisa del cilindro. Las interfaces se reproducirán mediante la realización de un movimiento alternativo lineal. <a href="https://nanovea.com/friction-wear-testing/">prueba de desgaste</a> con módulo de lubricante gota a gota.</p><p>El lubricante se aplicará a temperatura ambiente y en condiciones de calentamiento para comparar el arranque en frío y las condiciones óptimas de funcionamiento. Se observará el COF y la tasa de desgaste para comprender mejor cómo se comportan las interfaces en aplicaciones reales.</p>								</div>
				</div>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-cc2617d elementor-reverse-mobile elementor-section-full_width elementor-reverse-tablet elementor-section-height-default elementor-section-height-default" data-id="cc2617d" data-element_type="section">
						<div class="elementor-container elementor-column-gap-no">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-8c321eb" data-id="8c321eb" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-ac1fc7d elementor-widget elementor-widget-text-editor" data-id="ac1fc7d" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center; font-size: 20pt; color: black;">NANOVEA <span style="font-size: 20pt; color: #1b96cf;">T2000</span><br />Tribómetro de alta carga</p>								</div>
				</div>
		<div class="elementor-element elementor-element-20d76e0 e-grid e-con-full e-con e-child" data-id="20d76e0" data-element_type="container">
				<div class="elementor-element elementor-element-e3ede6d elementor-align-center homepage-button-brochure elementor-widget elementor-widget-button" data-id="e3ede6d" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
									<div class="elementor-button-wrapper">
					<a class="elementor-button elementor-button-link elementor-size-sm" href="https://nanovea.com/t2000-tribometer-brochure-form/" id="homepage-button-brochure">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">DESCARGAR FOLLETO</span>
					</span>
					</a>
				</div>
								</div>
				</div>
				<div class="elementor-element elementor-element-4e99e51 elementor-align-center homepage-button-quote elementor-widget elementor-widget-button" data-id="4e99e51" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
									<div class="elementor-button-wrapper">
					<a class="elementor-button elementor-button-link elementor-size-sm" href="https://nanovea.com/contact-sales-form/" id="homepage-button-quote">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">SOLICITAR PRESUPUESTO</span>
					</span>
					</a>
				</div>
								</div>
				</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-5fd6f7e" data-id="5fd6f7e" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-f307f9c elementor-widget elementor-widget-image" data-id="f307f9c" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
																<a href="https://nanovea.com/instruments/t2000/">
							<img decoding="async" width="591" height="579" src="https://nanovea.com/wp-content/uploads/2022/06/NANOVEA-Tribometer-T2000.png" class="elementor-animation-grow attachment-medium_large size-medium_large wp-image-20089" alt="Tribómetro neumático de alta carga NANOVEA T2000" />								</a>
															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-8ec771e elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="8ec771e" data-element_type="section" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4eba72c" data-id="4eba72c" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-eff073b elementor-widget elementor-widget-heading" data-id="eff073b" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">Parámetros y configuración de la prueba de desgaste del pistón</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-a2264cb elementor-widget elementor-widget-text-editor" data-id="a2264cb" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span style="color: #1b96cf;">CARGAR </span><span style="color: #1b96cf;"><span style="color: #000000;">............................ 100 N</span></span></p><p style="text-align: center;"><span style="color: #1b96cf;">DURACIÓN DE LA PRUEBA </span><span style="color: #1b96cf;"><span style="color: #000000;">............................ 30 minutos</span></span></p><p style="text-align: center;"><span style="color: #1b96cf;">VELOCIDAD <span style="color: #000000;">............................ 2000 rpm</span></span></p><p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">AMPLITUD </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;">............................ 10 mm</span></span></p><p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">DISTANCIA TOTAL </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;">............................ 1200 m</span></span></p><p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;"><span class="fontstyle0">REVESTIMIENTO DE LA FALDA </span><span class="fontstyle0"><span style="color: #000000;">............................ Moly-grafito</span></span></span></p><p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;"><span class="fontstyle0"><span class="fontstyle0">PIN MATERIAL </span><span class="fontstyle0"><span style="color: #000000;">............................ Aleación de aluminio 5052</span></span></span></span></p><p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;"><span class="fontstyle0"><span class="fontstyle0"><span class="fontstyle0">DIÁMETRO DEL PIN </span><span class="fontstyle0"><span style="color: #000000;">............................ 10 mm</span></span></span></span></span></p><p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;"><span class="fontstyle0"><span class="fontstyle0"><span class="fontstyle0"><span class="fontstyle0">LUBRICANTE </span><span class="fontstyle0"><span style="color: #000000;">............................ Aceite de motor (10W-30)</span></span></span></span></span></span></p><p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;"><span class="fontstyle0"><span class="fontstyle0"><span class="fontstyle0"><span class="fontstyle0"><span class="fontstyle0">CAUDAL APROX. CAUDAL </span><span class="fontstyle0"><span style="color: #000000;">............................ 60 mL/min</span></span></span></span></span></span></span></p><p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;"><span class="fontstyle0"><span class="fontstyle0"><span class="fontstyle0"><span class="fontstyle0"><span class="fontstyle0"><span class="fontstyle0">TEMPERATURA </span><span class="fontstyle0"><span style="color: #000000;">............................ Temperatura ambiente y 90°C</span></span></span></span></span></span></span></span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-966d446 elementor-reverse-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="966d446" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b861ac2" data-id="b861ac2" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-ba0fad2 elementor-widget elementor-widget-heading" data-id="ba0fad2" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">Relevancia real de<br> Pruebas de desgaste del pistón</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-dfc26fb elementor-widget elementor-widget-text-editor" data-id="dfc26fb" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: left;">Las pruebas de desgaste de pistones basadas en tribómetros proporcionan una visión crítica de cómo las elecciones de materiales y las estrategias de lubricación afectan a la fiabilidad real del motor. En lugar de depender de costosas pruebas en motores completos, los laboratorios pueden evaluar revestimientos, aceites y superficies de aleación en condiciones realistas de carga mecánica y temperatura. NANOVEA <a href="https://nanovea.com/profilometers/">Perfilometría 3D</a> y los módulos de tribología permiten cartografiar con precisión la profundidad de desgaste y la estabilidad de la fricción, lo que ayuda a los equipos de I+D a optimizar el rendimiento y reducir los ciclos de desarrollo.</p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-8bf8e24 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="8bf8e24" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-df0cd51" data-id="df0cd51" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-d5aa41c elementor-widget elementor-widget-heading" data-id="d5aa41c" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">Resultados y análisis de las pruebas de desgaste del pistón</h2>				</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-e9a9dbe elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="e9a9dbe" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-ff629e2" data-id="ff629e2" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-9fafc66 elementor-widget__width-initial elementor-widget elementor-widget-image" data-id="9fafc66" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="434" height="781" src="https://nanovea.com/wp-content/uploads/2021/09/Piston-Quality-Control-Linear-Reciprocating-Test.jpg" class="attachment-large size-large wp-image-15585" alt="comparación de la cicatriz de desgaste del pistón a partir de la prueba de desgaste lubricada por tribómetro" />															</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-555a9c8" data-id="555a9c8" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-fba89aa elementor-widget elementor-widget-text-editor" data-id="fba89aa" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>En este experimento, se utilizó A5052 como contramaterial. Aunque los bloques de motor suelen estar hechos de aluminio fundido, como el A356, el A5052 tiene propiedades mecánicas similares al A356 para este ensayo de simulación [1].</p><p>En las condiciones de ensayo, se observó un desgaste significativo en la falda del pistón a temperatura ambiente en comparación con 90°C. Los profundos arañazos observados en las muestras sugieren que el contacto entre el material estático y la falda del pistón se produce con frecuencia a lo largo de la prueba. La alta viscosidad a temperatura ambiente puede impedir que el aceite llene completamente los huecos en las interfaces y cree contacto metal-metal. A mayor temperatura, el aceite se diluye y puede fluir entre el bulón y el pistón. Como resultado, se observa un desgaste significativamente menor a mayor temperatura. La FIGURA 5 muestra que un lado de la cicatriz de desgaste se desgasta mucho menos que el otro. Esto se debe probablemente a la ubicación de la salida de aceite. El espesor de la película lubricante era mayor en un lado que en el otro, lo que provocó un desgaste desigual.</p>								</div>
				</div>
				<div class="elementor-element elementor-element-ce71809 elementor-widget elementor-widget-text-editor" data-id="ce71809" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: left;">[1] "Aluminio 5052 frente a aluminio 356.0". MakeItFrom.com, makeitfrom.com/compare/5052-O-Aluminum/A356.0-SG70B-A13560-Cast-Aluminum</p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-d06fc2c elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="d06fc2c" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-87bc6a7" data-id="87bc6a7" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-417b521 elementor-widget elementor-widget-text-editor" data-id="417b521" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<span class="fontstyle0">El COF de los ensayos tribológicos alternativos lineales puede dividirse en paso alto y paso bajo. El paso alto se refiere a la muestra que se mueve en la dirección de avance, o positiva, y el paso bajo se refiere a la muestra que se mueve en la dirección de retroceso, o negativa. Se observó que el COF medio del aceite RT era inferior a 0,1 en ambas direcciones. El COF medio entre pasadas fue de 0,072 y 0,080. Se observó que el COF medio del aceite a 90°C era diferente entre pasadas. Se observaron valores medios de COF de 0,167 y 0,09. La diferencia en el COF es una prueba adicional de que el aceite sólo fue capaz de humedecer correctamente un lado del pasador. Se obtuvo un COF elevado cuando se formó una película gruesa entre el bulón y la falda del pistón debido a que se produjo una lubricación hidrodinámica. Se observa un COF más bajo en la otra dirección cuando se produce una lubricación mixta. Para obtener más información sobre la lubricación hidrodinámica y la lubricación mixta, visite nuestra nota de aplicación en </span><span class="fontstyle2">Curvas Stribeck</span><span class="fontstyle0">.</span>								</div>
				</div>
				<div class="elementor-element elementor-element-70fb47f elementor-widget elementor-widget-image" data-id="70fb47f" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="1024" height="216" src="https://nanovea.com/wp-content/uploads/2021/09/Lubricated-wear-test-on-pistons-results.jpg" class="attachment-large size-large wp-image-15600" alt="resultados del coeficiente de fricción y del índice de desgaste de la prueba de desgaste del pistón lubricado" />															</div>
				</div>
				<div class="elementor-element elementor-element-94e8be6 elementor-widget elementor-widget-text-editor" data-id="94e8be6" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">Cuadro 1: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;">Resultados de la prueba de desgaste de pistones lubricados.</span></span></p>								</div>
				</div>
				<div class="elementor-element elementor-element-0d4ea18 elementor-widget elementor-widget-image" data-id="0d4ea18" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="1024" height="696" src="https://nanovea.com/wp-content/uploads/2021/09/Piston-COF-at-room-temperature-oil-wear-test.jpg" class="attachment-large size-large wp-image-15583" alt="gráficos del coeficiente de fricción para la prueba de desgaste del pistón a temperatura ambiente que muestran los perfiles de paso alto y bajo en bruto" />															</div>
				</div>
				<div class="elementor-element elementor-element-e330a1e elementor-widget elementor-widget-text-editor" data-id="e330a1e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 1: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;">Gráficos COF para la prueba de desgaste del aceite a temperatura ambiente A perfil bruto B paso alto C paso bajo.</span></span></p>								</div>
				</div>
				<div class="elementor-element elementor-element-6cf41bc elementor-widget elementor-widget-image" data-id="6cf41bc" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="1024" height="723" src="https://nanovea.com/wp-content/uploads/2021/09/Piston-COF-for-90°C-wear-oil-test-wear-test.jpg" class="attachment-large size-large wp-image-15607" alt="gráficos del coeficiente de fricción para la prueba de desgaste del pistón a 90 grados centígrados que muestran los perfiles de paso alto y bajo en bruto" />															</div>
				</div>
				<div class="elementor-element elementor-element-815568d elementor-widget elementor-widget-text-editor" data-id="815568d" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 2: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;">Gráficos COF para la prueba de aceite de desgaste a 90°C A perfil bruto B paso alto C paso bajo.</span></span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-dcd93aa elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="dcd93aa" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ecc2524" data-id="ecc2524" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<section class="elementor-section elementor-inner-section elementor-element elementor-element-0e3f6a7 elementor-reverse-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="0e3f6a7" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-7ac0513" data-id="7ac0513" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-c48a2b0 elementor-widget elementor-widget-image" data-id="c48a2b0" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="514" height="383" src="https://nanovea.com/wp-content/uploads/2021/09/Wear-scar-from-motor-oil-wear-test.jpg" class="attachment-large size-large wp-image-15608" alt="imagen al microscopio óptico de la cicatriz de desgaste del pistón en la prueba de desgaste del aceite de motor a temperatura ambiente" />															</div>
				</div>
				<div class="elementor-element elementor-element-75e2420 elementor-widget elementor-widget-text-editor" data-id="75e2420" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 3: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;">Imagen óptica de la cicatriz de desgaste de la prueba de desgaste del aceite de motor RT.</span></span></p>								</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-3bdc429" data-id="3bdc429" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-6b7f0b2 elementor-widget elementor-widget-image" data-id="6b7f0b2" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="901" height="722" src="https://nanovea.com/wp-content/uploads/2021/09/Piston-Quality-Control-Test.png" class="attachment-large size-large wp-image-15573" alt="superficie del pistón con cicatriz de desgaste localizada resaltada para el análisis tribológico" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-1f586f5 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="1f586f5" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-9fc4436" data-id="9fc4436" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-08ffa9a elementor-widget elementor-widget-image" data-id="08ffa9a" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="644" height="420" src="https://nanovea.com/wp-content/uploads/2021/09/Wear-Volume-analysis-of-wear-scar-from-motor-oil-quality-test.jpg" class="attachment-large size-large wp-image-15610" alt="análisis de volumen y profundidad de la cicatriz de desgaste del pistón a partir de la prueba del tribómetro" />															</div>
				</div>
				<div class="elementor-element elementor-element-c0fdc2a elementor-widget elementor-widget-text-editor" data-id="c0fdc2a" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 4: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;">Volumen de un análisis del agujero de la cicatriz de desgaste de la prueba de desgaste del aceite de motor RT.</span></span></p>								</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-5959008" data-id="5959008" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-aa00f25 elementor-widget elementor-widget-image" data-id="aa00f25" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="541" height="384" src="https://nanovea.com/wp-content/uploads/2021/09/Profilometry-scan-of-wear-scar-motor-oil-wear-test.jpg" class="attachment-large size-large wp-image-15576" alt="Perfilometría de superficie 3D de la cicatriz de desgaste del pistón que muestra la profundidad de desgaste y la rugosidad" />															</div>
				</div>
				<div class="elementor-element elementor-element-082cfdf elementor-widget elementor-widget-text-editor" data-id="082cfdf" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 5: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;">Escaneado perfilométrico de la cicatriz de desgaste de la prueba de desgaste del aceite de motor RT.</span></span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-1412b98 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="1412b98" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6d28914" data-id="6d28914" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<section class="elementor-section elementor-inner-section elementor-element elementor-element-88fc723 elementor-reverse-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="88fc723" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-4d582b0" data-id="4d582b0" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-1bcffdb elementor-widget elementor-widget-image" data-id="1bcffdb" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="514" height="383" src="https://nanovea.com/wp-content/uploads/2021/09/Wear-scar-from-90°C-motor-oil-wear-test.jpg" class="attachment-large size-large wp-image-15612" alt="imagen al microscopio óptico de la cicatriz de desgaste del pistón en la prueba de desgaste del aceite de motor a 90 grados" />															</div>
				</div>
				<div class="elementor-element elementor-element-bfa2a5d elementor-widget elementor-widget-text-editor" data-id="bfa2a5d" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 6: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;">Imagen óptica de la cicatriz de desgaste de la prueba de desgaste de aceite de motor a 90°C</span></span></p>								</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-0e809d5" data-id="0e809d5" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-4c1979f elementor-widget elementor-widget-image" data-id="4c1979f" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="902" height="722" src="https://nanovea.com/wp-content/uploads/2021/09/Piston-failure-lab-testing.png" class="attachment-large size-large wp-image-15601" alt="falda del pistón mostrando la zona de desgaste analizada durante la prueba de desgaste del pistón tribómetro" />															</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-inner-section elementor-element elementor-element-4a83181 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="4a83181" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-60a768c" data-id="60a768c" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-4bb06ac elementor-widget elementor-widget-image" data-id="4bb06ac" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="644" height="421" src="https://nanovea.com/wp-content/uploads/2021/09/Wear-Volume-analysis-of-wear-scar-from-90°C-motor-oil-quality-test.jpg" class="attachment-large size-large wp-image-15613" alt="medición del volumen y la profundidad de la cicatriz de desgaste del pistón a partir de la prueba del tribómetro de aceite de motor de 90 grados" />															</div>
				</div>
				<div class="elementor-element elementor-element-3cee7a2 elementor-widget elementor-widget-text-editor" data-id="3cee7a2" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 7: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;">Volumen de un análisis de agujero de la cicatriz de desgaste de la prueba de desgaste de aceite de motor a 90°C.</span></span></p>								</div>
				</div>
					</div>
		</div>
				<div class="elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-bb19159" data-id="bb19159" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-1c2d053 elementor-widget elementor-widget-image" data-id="1c2d053" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="564" height="382" src="https://nanovea.com/wp-content/uploads/2021/09/Profilometry-scan-of-wear-scar-from-90°C-motor-oil-wear-test.jpg" class="attachment-large size-large wp-image-15575" alt="Escaneado de perfilometría de superficie 3D de la cicatriz de desgaste del pistón de una prueba de desgaste de aceite de motor de 90 grados que muestra la profundidad y la textura del desgaste." />															</div>
				</div>
				<div class="elementor-element elementor-element-efa8b89 elementor-widget elementor-widget-text-editor" data-id="efa8b89" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: center;"><span class="fontstyle0" style="color: #1b96cf;">FIGURA 8: </span><span class="fontstyle0" style="color: #1b96cf;"><span style="color: #000000;">Escaneado perfilométrico de la cicatriz de desgaste de la prueba de desgaste de aceite de motor a 90°C.</span></span></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-7978715 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="7978715" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4c23c16" data-id="4c23c16" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-8843a9f elementor-widget elementor-widget-heading" data-id="8843a9f" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">Conclusiones: Evaluación del desgaste del motor con tribómetros NANOVEA</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-18f7f2e elementor-widget elementor-widget-text-editor" data-id="18f7f2e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>Se realizaron pruebas de desgaste alternativo lineal lubricado en un pistón para simular lo que ocurre en un motor operativo real. La interfaz entre la falda del pistón, el lubricante y la camisa del cilindro es crucial para el funcionamiento de un motor. El espesor del lubricante en la interfaz es responsable de la pérdida de energía debida a la fricción o al desgaste entre la falda del pistón y la camisa del cilindro. Para optimizar el motor, el espesor de la película debe ser lo más fino posible sin permitir que la falda del pistón y la camisa del cilindro se toquen. El reto, sin embargo, es cómo afectarán los cambios de temperatura, velocidad y fuerza a las interfaces P-L-C.</p><p>Con su amplio rango de carga (hasta 2000 N) y velocidad (hasta 15000 rpm), el tribómetro NANOVEA T2000 es capaz de simular diferentes condiciones posibles en un motor. Los posibles estudios futuros sobre este tema incluyen cómo se comportarán las interfaces P-L-C bajo diferentes cargas constantes, cargas oscilantes, temperatura del lubricante, velocidad y método de aplicación del lubricante. Estos parámetros pueden ajustarse fácilmente con el tribómetro NANOVEA T2000 para obtener una comprensión completa de los mecanismos de las interfaces falda del pistón-lubricante-guarnición del cilindro.</p>								</div>
				</div>
				<div class="elementor-element elementor-element-440e5b2 elementor-widget elementor-widget-text-editor" data-id="440e5b2" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>ℹ️<em data-start="1410" data-end="1468"> ¿Le interesa probar las pastillas de freno? Más información <a href="https://nanovea.com/brake-friction-tester/">comprobador de fricción de frenos</a> para pastillas, revestimientos e I+D en automoción.</em></p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-5019017 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="5019017" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-69990a9" data-id="69990a9" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-865c437 elementor-widget elementor-widget-heading" data-id="865c437" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">¿Tiene una aplicación similar?</h2>				</div>
				</div>
				<div class="elementor-element elementor-element-dacc386 elementor-align-justify open-chat elementor-widget elementor-widget-button" data-id="dacc386" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
									<div class="elementor-button-wrapper">
					<a class="elementor-button elementor-size-sm" role="button">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">HABLE AHORA CON UN EXPERTO</span>
					</span>
					</a>
				</div>
								</div>
				</div>
				<div class="elementor-element elementor-element-090edaa elementor-align-justify button-quote elementor-widget elementor-widget-button" data-id="090edaa" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
									<div class="elementor-button-wrapper">
					<a class="elementor-button elementor-button-link elementor-size-sm" href="https://nanovea.com/contact-sales-form/" id="button-quote-bottom">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">OBTENGA PRECIOS Y DETALLES RÁPIDAMENTE</span>
					</span>
					</a>
				</div>
								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div><p>The post <a href="https://nanovea.com/es/prueba-de-desgaste-del-piston/">Piston Wear Testing</a> appeared first on <a href="https://nanovea.com/es">NANOVEA: Advanced Profilometers, Tribometers, Nanoindenters, and Scratch Testers for Materials Testing</a>.</p>
]]></content:encoded>
					
					<wfw:commentrss>https://nanovea.com/es/prueba-de-desgaste-del-piston/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Medición continua de la curva de Stribeck utilizando un tribómetro de disco con pasador</title>
		<link>https://nanovea.com/es/medicion-de-la-curva-continua-en-el-disco-del-tribometro/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=continuous-stribeck-curve-measurement-using-pin-on-disk-tribometer</link>
					<comments>https://nanovea.com/es/medicion-de-la-curva-continua-en-el-disco-del-tribometro/#respond</comments>
		
		<dc:creator><![CDATA[nanovea]]></dc:creator>
		<pubdate>Mon, 14 Oct 2019 17:40:51 +0000</pubdate>
				<category><![CDATA[Application Notes]]></category>
		<category><![CDATA[Laboratory Testing]]></category>
		<category><![CDATA[Liquid Tribology]]></category>
		<category><![CDATA[Rotational Tribology]]></category>
		<category><![CDATA[Tribology Testing]]></category>
		<guid ispermalink="false">https://nanovea.com/?p=6978</guid>

					<description><![CDATA[<p>Introduction: When lubrication is applied to reduce the wear/friction of moving surfaces, the lubrication contact at the interface can shift from several regimes such as Boundary, Mixed and Hydrodynamic Lubrication. The thickness of the fluid film plays a major role in this process, mainly determined by the fluid viscosity, the load applied at the interface [&#8230;]</p>
<p>The post <a href="https://nanovea.com/es/medicion-de-la-curva-continua-en-el-disco-del-tribometro/">Continuous Stribeck Curve Measurement using Pin-on-Disk Tribometer</a> appeared first on <a href="https://nanovea.com/es">NANOVEA: Advanced Profilometers, Tribometers, Nanoindenters, and Scratch Testers for Materials Testing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Introducción:</strong></p>
<p>Cuando se aplica lubricación para reducir el desgaste y la fricción de las superficies en movimiento, el contacto de lubricación en la interfaz puede cambiar de varios regímenes, como la lubricación límite, mixta e hidrodinámica. El espesor de la película de fluido desempeña un papel importante en este proceso, determinado principalmente por la viscosidad del fluido, la carga aplicada en la interfaz y la velocidad relativa entre las dos superficies. La forma en que los regímenes de lubricación reaccionan a la fricción se muestra en lo que se denomina curva de Stribeck [1-4].</p>
<p>En este estudio demostramos por primera vez la capacidad de medir una curva de Stribeck continua. Utilizando el Nanovea <a href="https://nanovea.com/tribometers/">Tribómetro</a> Control de velocidad avanzado sin escalonamientos, de 15 000 a 0,01 rpm. En 10 minutos, el software proporciona directamente una curva de Stribeck completa. La sencilla configuración inicial solo requiere que los usuarios seleccionen el modo de rampa exponencial e introduzcan las velocidades inicial y final, en lugar de tener que realizar múltiples pruebas o programar un procedimiento por pasos a diferentes velocidades que requiere la unión de datos para las mediciones convencionales de la curva de Stribeck. Este avance proporciona datos precisos a lo largo de la evaluación del régimen de lubricación y reduce sustancialmente el tiempo y el costo. La prueba muestra un gran potencial para ser utilizada en diferentes aplicaciones de ingeniería industrial.</p>
<p>&nbsp;</p>
<p><a href="http://nanovea.com/App-Notes/stribeckcurvetribology.pdf"><img loading="lazy" decoding="async" class="alignnone wp-image-7075" src="https://nanovea.com/wp-content/uploads/2019/10/COVER-FOR-tribo-fixed.jpg" alt="" width="598" height="774" /></a></p>
<p><a href="http://nanovea.com/App-Notes/stribeckcurvetribology.pdf">¡Haz clic para leer más!</a></p><p>The post <a href="https://nanovea.com/es/medicion-de-la-curva-continua-en-el-disco-del-tribometro/">Continuous Stribeck Curve Measurement using Pin-on-Disk Tribometer</a> appeared first on <a href="https://nanovea.com/es">NANOVEA: Advanced Profilometers, Tribometers, Nanoindenters, and Scratch Testers for Materials Testing</a>.</p>
]]></content:encoded>
					
					<wfw:commentrss>https://nanovea.com/es/medicion-de-la-curva-continua-en-el-disco-del-tribometro/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Comparación de gotas lubricantes para los ojos utilizando el tribómetro Nanovea T50</title>
		<link>https://nanovea.com/es/comparacion-de-la-lubricacion-del-ojo-con-el-tribometro-nanovea-t50/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=lubricating-eye-drop-comparison-using-the-nanovea-t50-tribometer</link>
					<comments>https://nanovea.com/es/comparacion-de-la-lubricacion-del-ojo-con-el-tribometro-nanovea-t50/#respond</comments>
		
		<dc:creator><![CDATA[nanovea]]></dc:creator>
		<pubdate>Wed, 04 Sep 2019 16:59:53 +0000</pubdate>
				<category><![CDATA[Application Notes]]></category>
		<category><![CDATA[Laboratory Testing]]></category>
		<category><![CDATA[Liquid Tribology]]></category>
		<category><![CDATA[Rotational Tribology]]></category>
		<category><![CDATA[Tribology Testing]]></category>
		<guid ispermalink="false">https://nanovea.com/?p=6927</guid>

					<description><![CDATA[<p>Importance of Testing Eye Drop Solutions Eye drop solutions are used to alleviate symptoms caused by a range of eye problems. For example, they can be used to treat minor eye irritation (e.g. dryness and redness), delay the onset of glaucoma or treat infections. Eye drop solutions sold over-the-counter are mainly used to treat dryness. [&#8230;]</p>
<p>The post <a href="https://nanovea.com/es/comparacion-de-la-lubricacion-del-ojo-con-el-tribometro-nanovea-t50/">Lubricating Eye Drop Comparison using the Nanovea T50 Tribometer</a> appeared first on <a href="https://nanovea.com/es">NANOVEA: Advanced Profilometers, Tribometers, Nanoindenters, and Scratch Testers for Materials Testing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div data-elementor-type="wp-post" data-elementor-id="6927" class="elementor elementor-6927" data-elementor-post-type="post">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-21cd638d elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="21cd638d" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-42ec104d" data-id="42ec104d" data-element_type="column" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
			<div class="elementor-widget-wrap">
							</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-42d11421 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="42d11421" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-55297c0c" data-id="55297c0c" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-6ba397b8 elementor-widget elementor-widget-text-editor" data-id="6ba397b8" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p style="text-align: left; color: #1b96cf; font-size: 24px;">Importancia de probar las soluciones oftálmicas<strong><u><i><br></i></u></strong></p>
<div>Las soluciones oftálmicas se utilizan para aliviar los síntomas causados por diversos problemas oculares. Por ejemplo, pueden utilizarse para tratar irritaciones oculares leves (como sequedad y enrojecimiento), retrasar la aparición del glaucoma o tratar infecciones. Las soluciones oftálmicas de venta libre se utilizan principalmente para tratar la sequedad. Su eficacia para lubricar el ojo puede compararse y medirse con una prueba de coeficiente de fricción.</div>
<div>&nbsp;</div>
<div>La sequedad ocular puede deberse a una amplia variedad de factores, como la fatiga visual por el uso del ordenador o la exposición a condiciones climáticas extremas al aire libre. Unas buenas gotas lubricantes para los ojos ayudan a mantener y complementar la humedad de la superficie externa de los ojos. Esto alivia las molestias, el ardor, la irritación y el enrojecimiento asociados a la sequedad ocular. Mediante la medición del coeficiente de fricción (COF) de una solución oftálmica, se puede determinar su eficacia lubricante y compararla con otras soluciones.</div>

<p style="text-align: left; color: #1b96cf; font-size: 24px;">Objetivo de medición</p>
<p>En este estudio, se midió el coeficiente de fricción (COF) de tres soluciones lubricantes diferentes para gotas oftálmicas utilizando la configuración de pin sobre disco en el tribómetro Nanovea T50.</p>
<div style="text-align: center;"><a href="https://nanovea.com/wp-content/uploads/2019/09/Measurement-objective-picture.png"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-8113" src="https://nanovea.com/wp-content/uploads/2019/09/Measurement-objective-picture.png" alt="" width="917" height="649"></a></div>
<p style="text-align: left; color: #1b96cf; font-size: 24px;">Procedimiento de ensayo y procedimientos<strong><u><i><br></i></u></strong></p>
<p>Se aplicó un pasador esférico de alúmina de 6 mm de diámetro a un portaobjetos de vidrio, utilizando cada solución oftálmica como lubricante entre las dos superficies. Los parámetros de prueba utilizados en todos los experimentos se resumen en la tabla 1 a continuación.</p>
<div style="text-align: center;"><a href="https://nanovea.com/wp-content/uploads/2019/09/Samples-picture.png"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-8114" src="https://nanovea.com/wp-content/uploads/2019/09/Samples-picture.png" alt="" width="604" height="805"></a></div>
<p style="text-align: left; color: #1b96cf; font-size: 24px;">Resultados y debate<u><i></i></u></p>
<p style="margin: 0in; margin-bottom: .0001pt;"><span style="font-family: 'Arial',sans-serif;">Los valores máximos, mínimos y medios del coeficiente de fricción para las tres soluciones oftálmicas diferentes probadas se recogen en la tabla 2 a continuación. Los gráficos del COF frente a las revoluciones para cada solución oftálmica se muestran en las figuras 2-4. El COF durante cada prueba se mantuvo relativamente constante durante la mayor parte de la duración total de la prueba. La muestra A tuvo el COF medio más bajo, lo que indica que tenía las mejores propiedades lubricantes.</span></p>
<p style="margin: 0in; margin-bottom: .0001pt;"><span style="font-family: 'Arial',sans-serif; color: #1c1e29;">&nbsp;</span></p>
<p><a href="https://nanovea.com/wp-content/uploads/2019/09/Figure-2.png"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-8115" src="https://nanovea.com/wp-content/uploads/2019/09/Figure-2.png" alt="" width="1001" height="893"></a></p>
<p><a href="https://nanovea.com/wp-content/uploads/2019/09/Figure-3.png"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-8116" src="https://nanovea.com/wp-content/uploads/2019/09/Figure-3.png" alt="" width="1285" height="776"></a></p>
<p><a href="https://nanovea.com/wp-content/uploads/2019/09/Figure-4.png"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-8117" src="https://nanovea.com/wp-content/uploads/2019/09/Figure-4.png" alt="" width="1267" height="794"></a></p>
<p style="text-align: left; color: #1b96cf; font-size: 24px;">Conclusión</p>
<p><a href="https://nanovea.com/wp-content/uploads/2019/09/CoefficientofFrictionofEyeDrop.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-8121" src="https://nanovea.com/wp-content/uploads/2019/09/CoefficientofFrictionofEyeDrop.jpg" alt="" width="1216" height="777"></a></p>
<p>En este estudio mostramos la capacidad del tribómetro Nanovea T50 para medir el coeficiente de fricción de tres soluciones oftálmicas. A partir de estos valores, demostramos que la muestra A tenía un coeficiente de fricción más bajo y, por lo tanto, presentaba una mejor lubricación en comparación con las otras dos muestras.</p>
<p>Nanovea <a href="https://nanovea.com/tribometers/">Tribómetros </a>ofrece pruebas de desgaste y fricción precisas y repetibles utilizando módulos rotativos y lineales que cumplen con las normas ISO y ASTM. También proporciona módulos opcionales de desgaste a alta temperatura, lubricación y tribocorrosión disponibles en un sistema preintegrado. Esta versatilidad permite a los usuarios simular mejor el entorno de aplicación real y mejorar la comprensión fundamental del mecanismo de desgaste y las características tribológicas de diversos materiales.</p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				<section class="elementor-section elementor-top-section elementor-element elementor-element-2f41878 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="2f41878" data-element_type="section" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a6030dc" data-id="a6030dc" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-acb17e4 elementor-widget elementor-widget-heading" data-id="acb17e4" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default"><b>AHORA, HABLEMOS DE SU SOLICITUD</b></h2>				</div>
				</div>
				<div class="elementor-element elementor-element-f96103e live-chat elementor-align-center elementor-widget elementor-widget-button" data-id="f96103e" data-element_type="widget" data-widget_type="button.default">
				<div class="elementor-widget-container">
									<div class="elementor-button-wrapper">
					<a class="elementor-button elementor-button-link elementor-size-md" href="https://nanovea.com/contact/live-chat/" id="live-chat">
						<span class="elementor-button-content-wrapper">
									<span class="elementor-button-text">CHAT EN VIVO</span>
					</span>
					</a>
				</div>
								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div><p>The post <a href="https://nanovea.com/es/comparacion-de-la-lubricacion-del-ojo-con-el-tribometro-nanovea-t50/">Lubricating Eye Drop Comparison using the Nanovea T50 Tribometer</a> appeared first on <a href="https://nanovea.com/es">NANOVEA: Advanced Profilometers, Tribometers, Nanoindenters, and Scratch Testers for Materials Testing</a>.</p>
]]></content:encoded>
					
					<wfw:commentrss>https://nanovea.com/es/comparacion-de-la-lubricacion-del-ojo-con-el-tribometro-nanovea-t50/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Rigidez de las cerdas del cepillo Rendimiento utilizando un tribómetro</title>
		<link>https://nanovea.com/es/cepillo-cerda-rigidez/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=brush-bristle-stiffness</link>
					<comments>https://nanovea.com/es/cepillo-cerda-rigidez/#respond</comments>
		
		<dc:creator><![CDATA[nanovea]]></dc:creator>
		<pubdate>Tue, 28 Jun 2016 21:14:00 +0000</pubdate>
				<category><![CDATA[Application Notes]]></category>
		<category><![CDATA[Laboratory Testing]]></category>
		<category><![CDATA[Linear Tribology]]></category>
		<category><![CDATA[Liquid Tribology]]></category>
		<category><![CDATA[Tribology Testing]]></category>
		<category><![CDATA[Bristle Stiffness]]></category>
		<guid ispermalink="false">http://nanovea.com/?p=2426</guid>

					<description><![CDATA[<p>Brushes are among the most basic and widely used tools in the world. They can be used to remove material (toothbrush, archaeological brush, bench grinder brush), apply material (paintbrush, makeup brush, gilding brush), comb filaments, or add a pattern. As a result of the mechanical and abrasive forces on them, brushes constantly have to be [&#8230;]</p>
<p>The post <a href="https://nanovea.com/es/cepillo-cerda-rigidez/">Brush Bristle Stiffness Performance Using Tribometer</a> appeared first on <a href="https://nanovea.com/es">NANOVEA: Advanced Profilometers, Tribometers, Nanoindenters, and Scratch Testers for Materials Testing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Los cepillos se encuentran entre las herramientas más básicas y utilizadas en el mundo. Se pueden utilizar para eliminar material (cepillo de dientes, cepillo arqueológico, cepillo para amoladora de banco), aplicar material (pincel, brocha de maquillaje, brocha para dorar), peinar filamentos o añadir un patrón. Como resultado de las fuerzas mecánicas y abrasivas a las que están sometidos, los cepillos deben sustituirse constantemente tras un uso moderado. Por ejemplo, los cabezales de los cepillos de dientes deben sustituirse cada tres o cuatro meses debido al desgaste que se produce como resultado de su uso repetido. Si las fibras del cepillo de dientes son demasiado rígidas, se corre el riesgo de desgastar el diente en lugar de la placa blanda. Si las fibras del cepillo de dientes son demasiado blandas, el cepillo pierde su forma más rápidamente. Es necesario comprender la flexión cambiante del cepillo, así como el desgaste y el cambio general de forma de las fibras en diferentes condiciones de carga, para diseñar cepillos que se adapten mejor a su aplicación.</p>
<p><a href="https://nanovea.com/wp-content/themes/wp-nanovea/Application%20Notes/bristle-stiffness.pdf" target="_blank" rel="noopener noreferrer">Rigidez de las cerdas del cepillo Rendimiento utilizando un tribómetro</a></p><p>The post <a href="https://nanovea.com/es/cepillo-cerda-rigidez/">Brush Bristle Stiffness Performance Using Tribometer</a> appeared first on <a href="https://nanovea.com/es">NANOVEA: Advanced Profilometers, Tribometers, Nanoindenters, and Scratch Testers for Materials Testing</a>.</p>
]]></content:encoded>
					
					<wfw:commentrss>https://nanovea.com/es/cepillo-cerda-rigidez/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>