{"id":8190,"date":"2020-04-21T16:32:54","date_gmt":"2020-04-21T16:32:54","guid":{"rendered":"https:\/\/nanovea.com\/?p=8190"},"modified":"2023-11-13T23:24:07","modified_gmt":"2023-11-13T23:24:07","slug":"avaliacao-avaliacao-utilizacao-nanoindentacao-de-tecidos-biologicos","status":"publish","type":"post","link":"https:\/\/nanovea.com\/pt\/biological-tissue-hardness-evaluation-using-nanoindentation\/","title":{"rendered":"Avalia\u00e7\u00e3o da Dureza Biol\u00f3gica do Tecido usando Nanoindenta\u00e7\u00e3o"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"8190\" class=\"elementor elementor-8190\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3edf72c1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3edf72c1\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1636e0ac\" data-id=\"1636e0ac\" data-element_type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2842492 elementor-widget elementor-widget-heading\" data-id=\"2842492\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Import\u00e2ncia da Nanoindenta\u00e7\u00e3o Biol\u00f3gica de Tecidos <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-37f47654 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"37f47654\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-12a446e6\" data-id=\"12a446e6\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-472dae5d elementor-widget elementor-widget-text-editor\" data-id=\"472dae5d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Os testes mec\u00e2nicos tradicionais (dureza, ader\u00eancia, compress\u00e3o, pun\u00e7\u00e3o, resist\u00eancia \u00e0 ruptura, etc.) exigem maior precis\u00e3o e confiabilidade nos ambientes atuais de controle de qualidade com uma ampla gama de materiais avan\u00e7ados, desde tecidos at\u00e9 materiais fr\u00e1geis. A instrumenta\u00e7\u00e3o mec\u00e2nica tradicional n\u00e3o fornece o controle de carga sens\u00edvel e a resolu\u00e7\u00e3o necess\u00e1ria para materiais avan\u00e7ados. Os desafios associados aos biomateriais exigem o desenvolvimento de testes mec\u00e2nicos capazes de controlar com precis\u00e3o a carga de materiais extremamente macios. Estes materiais exigem cargas de teste sub mN muito baixas com grande alcance de profundidade para garantir a medi\u00e7\u00e3o adequada das propriedades. Al\u00e9m disso, muitos tipos diferentes de testes mec\u00e2nicos podem ser realizados em um \u00fanico sistema, permitindo uma maior funcionalidade. Isto fornece uma gama de medi\u00e7\u00f5es importantes sobre biomateriais, incluindo dureza, m\u00f3dulo el\u00e1stico, m\u00f3dulo de perda e armazenamento, al\u00e9m de resist\u00eancia a arranh\u00f5es e pontos de ruptura de resist\u00eancia ao escoamento.<\/p>\n<div>&nbsp;<\/div>\n\n<p style=\"text-align: left; color: #1b96cf; font-size: 24px;\">Objetivo da medi\u00e7\u00e3o<\/p>\n<p>Nesta aplica\u00e7\u00e3o o testador mec\u00e2nico Nanovea em modo nanoindenta\u00e7\u00e3o \u00e9 usado para estudar a dureza e o m\u00f3dulo el\u00e1stico de 3 \u00e1reas separadas de um substituto de biomaterial em regi\u00f5es de gordura, carne clara e carne escura de prosciutto.<\/p>\n<p>A nanoindenta\u00e7\u00e3o \u00e9 baseada nas normas de indenta\u00e7\u00e3o instrumentada ASTM E2546 e ISO 14577. Ela usa m\u00e9todos estabelecidos onde uma ponta de indenta\u00e7\u00e3o de geometria conhecida \u00e9 conduzida para um local espec\u00edfico do material de teste com uma carga normal crescente controlada. Ao atingir uma profundidade m\u00e1xima pr\u00e9-estabelecida, a carga normal \u00e9 reduzida at\u00e9 que ocorra um relaxamento completo. A carga \u00e9 aplicada por um atuador piezo e medida em um la\u00e7o controlado com uma c\u00e9lula de carga de alta sensibilidade. Durante os experimentos, a posi\u00e7\u00e3o de indentro em rela\u00e7\u00e3o \u00e0 superf\u00edcie da amostra \u00e9 monitorada com um sensor capacitivo de alta precis\u00e3o. As curvas de carga e deslocamento resultantes fornecem dados espec\u00edficos para a natureza mec\u00e2nica do material testado. Os modelos estabelecidos calculam a dureza quantitativa e os valores de m\u00f3dulo com os dados medidos. A nanoindenta\u00e7\u00e3o \u00e9 adequada para medi\u00e7\u00f5es de baixa carga e profundidade de penetra\u00e7\u00e3o em escalas nanom\u00e9tricas.<\/p>\n<p style=\"text-align: left; color: #1b96cf; font-size: 24px;\">Resultados e Discuss\u00e3o<u><i><\/i><\/u><\/p>\n<p style=\"margin: 0in; margin-bottom: .0001pt;\"><span style=\"font-family: 'Arial',sans-serif;\">Estas tabelas abaixo apresentam valores medidos de dureza e m\u00f3dulo de Young com m\u00e9dias e desvios padr\u00e3o. A elevada rugosidade superficial pode causar grandes varia\u00e7\u00f5es nos resultados devido ao pequeno tamanho do recuo.<br><\/span><\/p>\n<div style=\"text-align: center;\"><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Table-1-1.png\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-8194\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Table-1-1.png\" alt=\"\" width=\"540\" height=\"216\"><\/a><\/div>\n\n<p style=\"margin: 0in; margin-bottom: .0001pt;\"><span style=\"font-family: 'Arial',sans-serif; color: #1c1e29;\"> A \u00e1rea de gordura tinha cerca da metade da dureza das \u00e1reas de carne. O tratamento da carne fez com que a \u00e1rea mais escura da carne fosse mais dura do que a \u00e1rea mais clara. O m\u00f3dulo el\u00e1stico e a dureza est\u00e3o em rela\u00e7\u00e3o direta com a sensa\u00e7\u00e3o de mastigabilidade da boca das \u00e1reas de gordura e de carne. A \u00e1rea de gordura e de carne clara tem rastejamento continuando a uma taxa maior do que a de carne escura ap\u00f3s 60 segundos.<br><\/span><\/p>\n<p><em><strong>Resultados detalhados - Gordura<\/strong><\/em><\/p>\n\n<div style=\"text-align: center;\"><p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Fat-1.png\"><img decoding=\"async\" class=\"alignnone size-full wp-image-8196\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Fat-1.png\" alt=\"\" width=\"1137\" height=\"771\"><\/a><\/p>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Fat-2.png\"><img decoding=\"async\" class=\"alignnone size-full wp-image-8197\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Fat-2.png\" alt=\"\" width=\"1078\" height=\"562\"><\/a><\/p><\/div>\n<p><em><strong>Resultados detalhados - Carne leve<br><\/strong><\/em><\/p>\n\n<div style=\"text-align: center;\"><p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Light-Meat-1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8198\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Light-Meat-1.png\" alt=\"\" width=\"1135\" height=\"769\"><\/a><\/p>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Light-Meat-2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8199\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Light-Meat-2.png\" alt=\"\" width=\"1091\" height=\"573\"><\/a><\/p><\/div>\n<p><em><strong>Resultados detalhados - Carne escura<\/strong><\/em><\/p>\n\n<div style=\"text-align: center;\"><p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Dark-Meat-1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8200\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Dark-Meat-1.png\" alt=\"\" width=\"1074\" height=\"799\"><\/a><\/p>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Dark-Meat-2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8201\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/Dark-Meat-2.png\" alt=\"\" width=\"1377\" height=\"684\"><\/a><\/p><\/div>\n\n<p style=\"text-align: left; color: #1b96cf; font-size: 24px;\">Conclus\u00e3o<\/p>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/medic-563423_1920.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-8202\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/04\/medic-563423_1920.jpg\" alt=\"\" width=\"1920\" height=\"1280\"><\/a><\/p>\n<p>Nesta aplica\u00e7\u00e3o, o Nanovea <a href=\"https:\/\/nanovea.com\/mechanical-testers\/\">testador mec\u00e2nico<\/a> no modo de nanoindenta\u00e7\u00e3o, determinou de forma confi\u00e1vel as propriedades mec\u00e2nicas das \u00e1reas de gordura e carne, ao mesmo tempo em que superou a alta rugosidade da superf\u00edcie da amostra. Isto demonstrou a ampla e incompar\u00e1vel capacidade do testador mec\u00e2nico da Nanovea. O sistema fornece simultaneamente medi\u00e7\u00f5es precisas de propriedades mec\u00e2nicas em materiais extremamente duros e tecidos biol\u00f3gicos moles.<\/p>\n<p>A c\u00e9lula de carga em circuito fechado com a mesa piezoel\u00e9trica garante a medi\u00e7\u00e3o precisa de materiais em gel duros ou moles de 1 a 5kPa. Usando o mesmo sistema, \u00e9 poss\u00edvel testar biomateriais com cargas mais altas de at\u00e9 400N. A carga de m\u00faltiplos ciclos pode ser usada para testes de fadiga e as informa\u00e7\u00f5es de resist\u00eancia ao escoamento em cada zona podem ser obtidas usando uma ponta cil\u00edndrica plana de diamante. Al\u00e9m disso, com a An\u00e1lise Mec\u00e2nica Din\u00e2mica (DMA), a perda de propriedades viscoel\u00e1sticas e os m\u00f3dulos de armazenamento podem ser avaliados com alta precis\u00e3o usando o controle de carga em circuito fechado. Testes em v\u00e1rias temperaturas e sob l\u00edquidos tamb\u00e9m est\u00e3o dispon\u00edveis no mesmo sistema.<\/p>\n<p>O testador mec\u00e2nico da Nanovea continua sendo a ferramenta superior para aplica\u00e7\u00f5es biol\u00f3gicas e de pol\u00edmeros moles\/gel.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ae07565 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ae07565\" data-element_type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-64d6871\" data-id=\"64d6871\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0f2b6d8 elementor-widget elementor-widget-heading\" data-id=\"0f2b6d8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><b>AGORA, VAMOS FALAR SOBRE SUA APLICA\u00c7\u00c3O<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d552a0 live-chat elementor-align-center elementor-widget elementor-widget-button\" data-id=\"6d552a0\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/nanovea.com\/contact\/live-chat\/\" id=\"live-chat\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">CHAT AO VIVO<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Importance of Biological Tissue Nanoindentation Traditional mechanical tests (hardness, adhesion, compression, puncture, yield strength, etc.) require greater precision and reliability in today\u2019s quality control environments with a wide range of advanced materials from tissues to brittle materials. Traditional mechanical instrumentation fails to provide the sensitive load control and resolution required for advanced materials. The challenges [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":11687,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"footnotes":""},"categories":[7,338,349,337],"tags":[],"class_list":["post-8190","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","category-indentation-hardness-elastic","category-laboratory-testing","category-mechanical-testing"],"_links":{"self":[{"href":"https:\/\/nanovea.com\/pt\/wp-json\/wp\/v2\/posts\/8190","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nanovea.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nanovea.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nanovea.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/nanovea.com\/pt\/wp-json\/wp\/v2\/comments?post=8190"}],"version-history":[{"count":20,"href":"https:\/\/nanovea.com\/pt\/wp-json\/wp\/v2\/posts\/8190\/revisions"}],"predecessor-version":[{"id":23480,"href":"https:\/\/nanovea.com\/pt\/wp-json\/wp\/v2\/posts\/8190\/revisions\/23480"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nanovea.com\/pt\/wp-json\/wp\/v2\/media\/11687"}],"wp:attachment":[{"href":"https:\/\/nanovea.com\/pt\/wp-json\/wp\/v2\/media?parent=8190"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nanovea.com\/pt\/wp-json\/wp\/v2\/categories?post=8190"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nanovea.com\/pt\/wp-json\/wp\/v2\/tags?post=8190"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}