{"id":7272,"date":"2020-01-19T20:58:47","date_gmt":"2020-01-19T20:58:47","guid":{"rendered":"https:\/\/nanovea.com\/?p=7272"},"modified":"2023-11-08T23:22:31","modified_gmt":"2023-11-08T23:22:31","slug":"dimensional-and-surface-finish-of-polymeric-tubes","status":"publish","type":"post","link":"https:\/\/nanovea.com\/pl\/dimensional-and-surface-finish-of-polymeric-tubes\/","title":{"rendered":"Wymiary i wyko\u0144czenie powierzchni rur polimerowych"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7272\" class=\"elementor elementor-7272\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-217d542e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"217d542e\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2efdff33\" data-id=\"2efdff33\" data-element_type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-21152c32 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"21152c32\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4f3cbcd2\" data-id=\"4f3cbcd2\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1286dcf0 elementor-widget elementor-widget-text-editor\" data-id=\"1286dcf0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: left; color: #1b96cf; font-size: 24px;\">Znaczenie analizy wymiarowej i powierzchniowej rur polimerowych<strong><u><i><br \/><\/i><\/u><\/strong><\/p><p>Rury wykonane z materia\u0142u polimerowego s\u0105 powszechnie stosowane w wielu ga\u0142\u0119ziach przemys\u0142u, od motoryzacyjnej, medycznej, elektrycznej i wielu innych. W tym badaniu przy u\u017cyciu Nanovea badano cewniki medyczne wykonane z r\u00f3\u017cnych materia\u0142\u00f3w polimerowych <a href=\"https:\/\/nanovea.com\/profilometers\/\">Bezkontaktowy profilometr 3D<\/a> do pomiaru chropowato\u015bci powierzchni, morfologii i wymiar\u00f3w. Chropowato\u015b\u0107 powierzchni ma kluczowe znaczenie dla cewnik\u00f3w, poniewa\u017c wiele problem\u00f3w z cewnikami, w tym infekcje, urazy fizyczne i stany zapalne mog\u0105 by\u0107 zwi\u0105zane z powierzchni\u0105 cewnika. W\u0142a\u015bciwo\u015bci mechaniczne, takie jak wsp\u00f3\u0142czynnik tarcia, mo\u017cna r\u00f3wnie\u017c bada\u0107 poprzez obserwacj\u0119 w\u0142a\u015bciwo\u015bci powierzchni. Te wymierne dane mo\u017cna uzyska\u0107 w celu zapewnienia, \u017ce cewnik mo\u017ce by\u0107 u\u017cywany w zastosowaniach medycznych.<\/p><p>W por\u00f3wnaniu z mikroskopi\u0105 optyczn\u0105 i mikroskopi\u0105 elektronow\u0105, profilometria bezkontaktowa 3D wykorzystuj\u0105ca chromatyzm osiowy jest wysoce preferowana do charakteryzowania powierzchni cewnik\u00f3w ze wzgl\u0119du na mo\u017cliwo\u015b\u0107 pomiaru k\u0105t\u00f3w\/krzywizn, mo\u017cliwo\u015b\u0107 pomiaru powierzchni materia\u0142\u00f3w pomimo ich przezroczysto\u015bci lub refleksyjno\u015bci, minimalne przygotowanie pr\u00f3bki i nieinwazyjny charakter. W przeciwie\u0144stwie do konwencjonalnej mikroskopii optycznej, wysoko\u015b\u0107 powierzchni mo\u017ce by\u0107 uzyskana i wykorzystana do analizy obliczeniowej; np. znalezienie wymiar\u00f3w i usuni\u0119cie formy w celu znalezienia chropowato\u015bci powierzchni. Posiadanie niewielkiego przygotowania pr\u00f3bki, w przeciwie\u0144stwie do mikroskopii elektronowej, oraz bezkontaktowy charakter pozwala r\u00f3wnie\u017c na szybkie zbieranie danych bez obawy o zanieczyszczenie i b\u0142\u0105d zwi\u0105zany z przygotowaniem pr\u00f3bki.<\/p><p style=\"text-align: left; color: #1b96cf; font-size: 24px;\">Cel pomiaru<\/p><p>W tej aplikacji Nanovea 3D Non-Contact Profilometer jest u\u017cywany do skanowania powierzchni dw\u00f3ch cewnik\u00f3w: jednego wykonanego z TPE (Thermoplastic Elastomer) i drugiego z PVC (Polyvinyl Chloride). Uzyskane i por\u00f3wnane zostan\u0105 parametry morfologii, wymiaru promieniowego i wysoko\u015bci obu cewnik\u00f3w.<\/p><p>\u00a0<\/p><div style=\"text-align: center;\"><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/Polymeric-Tube-Measurement-Objectives.png\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-7678 aligncenter\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/Polymeric-Tube-Measurement-Objectives.png\" alt=\"\" width=\"640\" height=\"638\" \/><\/a><\/div><p>\u00a0<\/p><p style=\"text-align: left; color: #1b96cf; font-size: 24px;\">Wyniki i dyskusja<strong><u><i><br \/><\/i><\/u><\/strong><\/p><p><strong style=\"color: black;\"><i>Powierzchnia 3D<\/i><\/strong><\/p><p>Pomimo krzywizny na rurkach polimerowych, profilometr bezkontaktowy Nanovea 3D mo\u017ce skanowa\u0107 powierzchni\u0119 cewnik\u00f3w. Z wykonanego skanu mo\u017cna uzyska\u0107 obraz 3D do szybkiej, bezpo\u015bredniej kontroli wizualnej powierzchni.<\/p><div style=\"padding-left: 4%;\"><p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/TPE-Catheter-with-label.png\"><img decoding=\"async\" class=\"alignnone size-full wp-image-7682\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/TPE-Catheter-with-label.png\" alt=\"\" width=\"580\" height=\"634\" \/><\/a><\/p><div style=\"text-align: left;\">\u00a0<\/div><div><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/PVC-Catheter.png\"><img decoding=\"async\" class=\"alignnone size-full wp-image-7683\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/PVC-Catheter.png\" alt=\"\" width=\"580\" height=\"704\" \/><\/a><\/div><\/div><div>\u00a0<\/div><p>\u00a0<\/p><div style=\"text-align: left;\"><em><strong style=\"color: black;\">Analiza dwuwymiarowa<\/strong><\/em><\/div><p>Zewn\u0119trzny wymiar promieniowy zosta\u0142 uzyskany poprzez wyodr\u0119bnienie profilu z oryginalnego skanu i dopasowanie \u0142uku do profilu. Pokazuje to zdolno\u015b\u0107 profilometru bezkontaktowego 3D do przeprowadzania szybkiej analizy wymiarowej w zastosowaniach zwi\u0105zanych z kontrol\u0105 jako\u015bci. Mo\u017cna r\u00f3wnie\u017c \u0142atwo uzyska\u0107 wiele profili wzd\u0142u\u017c d\u0142ugo\u015bci cewnika.<\/p><div style=\"padding-left: 8%;\"><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2019\/12\/2d-dimensional-analysis-tpe-and-pvc.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7581\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2019\/12\/2d-dimensional-analysis-tpe-and-pvc.png\" alt=\"\" width=\"580\" height=\"552\" \/><\/a><\/div><div>\u00a0<\/div><p>\u00a0<\/p><div style=\"text-align: left;\"><em><strong style=\"color: black;\">Analiza powierzchni Chropowato\u015b\u0107<\/strong><\/em><\/div><p>Zewn\u0119trzny wymiar promieniowy zosta\u0142 uzyskany poprzez wyodr\u0119bnienie profilu z oryginalnego skanu i dopasowanie \u0142uku do profilu. Pokazuje to zdolno\u015b\u0107 profilometru bezkontaktowego 3D do przeprowadzania szybkiej analizy wymiarowej w zastosowaniach zwi\u0105zanych z kontrol\u0105 jako\u015bci. Mo\u017cna r\u00f3wnie\u017c \u0142atwo uzyska\u0107 wiele profili wzd\u0142u\u017c d\u0142ugo\u015bci cewnika.<\/p><div style=\"padding-left: 6%; width: 80%;\"><p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/surface-2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-7761 aligncenter\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/surface-2.png\" alt=\"\" width=\"2010\" height=\"2292\" \/><\/a><\/p><p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/surface-1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7762\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/surface-1.png\" alt=\"\" width=\"1986\" height=\"2700\" \/><\/a><\/p><\/div><p style=\"text-align: left; color: #1b96cf; font-size: 24px;\">Wniosek<\/p><p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/polymetric-tube.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7646\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/polymetric-tube.png\" alt=\"\" width=\"1920\" height=\"776\" \/><\/a><\/p><p>W tej aplikacji pokazali\u015bmy, jak bezkontaktowy profilometr Nanovea 3D mo\u017ce by\u0107 wykorzystany do charakteryzowania rur polimerowych. Konkretnie, metrologia powierzchni, wymiary promieniowe i chropowato\u015b\u0107 powierzchni zosta\u0142y uzyskane dla cewnik\u00f3w medycznych. Stwierdzono, \u017ce promie\u0144 zewn\u0119trzny cewnika z TPE wynosi 2,40 mm, natomiast cewnika z PVC 1,27 mm. Stwierdzono, \u017ce powierzchnia cewnika z TPE jest bardziej szorstka ni\u017c cewnika z PVC. Sa TPE wynosi\u0142a 0,9740\u00b5m w por\u00f3wnaniu z 0,1791\u00b5m PVC. Chocia\u017c do bada\u0144 u\u017cyto cewnik\u00f3w medycznych, profilometria bezkontaktowa 3D mo\u017ce by\u0107 stosowana r\u00f3wnie\u017c do wielu r\u00f3\u017cnych powierzchni. Mo\u017cliwe do uzyskania dane i obliczenia nie s\u0105 ograniczone do tego, co jest pokazane.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d5b7c53 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d5b7c53\" data-element_type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a9c0923\" data-id=\"a9c0923\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3d0d2a8 elementor-widget elementor-widget-heading\" data-id=\"3d0d2a8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><b>TERAZ POROZMAWIAJMY O TWOJEJ APLIKACJI<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bc9e705 live-chat elementor-align-center elementor-widget elementor-widget-button\" data-id=\"bc9e705\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/nanovea.com\/contact\/live-chat\/\" id=\"live-chat\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">LIVE CHAT<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Importance of Dimensional and Surface Analysis of Polymeric Tubes Tubes made from polymeric material are commonly used in many industries ranging from automotive, medical, electrical, and many other categories. In this study, medical catheters made of different polymeric materials were studied using the Nanovea 3D Non-Contact Profilometer to measure surface roughness, morphology, and dimensions. Surface [&hellip;]<\/p>","protected":false},"author":1,"featured_media":11700,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"footnotes":""},"categories":[7,349,350,351,335],"tags":[],"class_list":["post-7272","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","category-laboratory-testing","category-profilometry-geometry-shape","category-profilometry-roughness-finish","category-profilometry-testing"],"_links":{"self":[{"href":"https:\/\/nanovea.com\/pl\/wp-json\/wp\/v2\/posts\/7272","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nanovea.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nanovea.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nanovea.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/nanovea.com\/pl\/wp-json\/wp\/v2\/comments?post=7272"}],"version-history":[{"count":60,"href":"https:\/\/nanovea.com\/pl\/wp-json\/wp\/v2\/posts\/7272\/revisions"}],"predecessor-version":[{"id":23349,"href":"https:\/\/nanovea.com\/pl\/wp-json\/wp\/v2\/posts\/7272\/revisions\/23349"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nanovea.com\/pl\/wp-json\/wp\/v2\/media\/11700"}],"wp:attachment":[{"href":"https:\/\/nanovea.com\/pl\/wp-json\/wp\/v2\/media?parent=7272"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nanovea.com\/pl\/wp-json\/wp\/v2\/categories?post=7272"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nanovea.com\/pl\/wp-json\/wp\/v2\/tags?post=7272"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}