{"id":7623,"date":"2020-01-19T18:46:50","date_gmt":"2020-01-19T18:46:50","guid":{"rendered":"https:\/\/nanovea.com\/?p=7623"},"modified":"2023-11-13T23:27:09","modified_gmt":"2023-11-13T23:27:09","slug":"evaluacion-de-la-dureza-de-los-dientes-con-nanoindentacion","status":"publish","type":"post","link":"https:\/\/nanovea.com\/es\/evaluacion-de-la-dureza-de-los-dientes-con-nanoindentacion\/","title":{"rendered":"Evaluaci\u00f3n de la dureza dental mediante nanoindentaci\u00f3n"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7623\" class=\"elementor elementor-7623\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1718cc9c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1718cc9c\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-30e5436f\" data-id=\"30e5436f\" data-element_type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-45b4a270 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"45b4a270\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-48fca1fb\" data-id=\"48fca1fb\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7a73046b elementor-widget elementor-widget-text-editor\" data-id=\"7a73046b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: left; color: #1b96cf; font-size: 24px;\">Importancia de la nanoindentaci\u00f3n para los biomateriales<u><i><\/i><\/u><\/p><p><strong><u><i>\u00a0<\/i><\/u><\/strong><br \/>Con muchas pruebas mec\u00e1nicas tradicionales (dureza, adhesi\u00f3n, compresi\u00f3n, perforaci\u00f3n, l\u00edmite el\u00e1stico, etc.), los entornos actuales de control de calidad con materiales sensibles avanzados, desde geles hasta materiales fr\u00e1giles, requieren ahora un mayor control de la precisi\u00f3n y la fiabilidad. Los instrumentos mec\u00e1nicos tradicionales no proporcionan el control de carga sensible y la resoluci\u00f3n necesarios, ya que est\u00e1n dise\u00f1ados para utilizarse con materiales a granel. A medida que el tama\u00f1o de los materiales sometidos a prueba cobr\u00f3 mayor inter\u00e9s, se desarroll\u00f3 <a href=\"https:\/\/nanovea.com\/nano-indentation-tester\/\">Nanoindentaci\u00f3n<\/a> proporcion\u00f3 un m\u00e9todo confiable para obtener informaci\u00f3n mec\u00e1nica esencial en superficies m\u00e1s peque\u00f1as, como la investigaci\u00f3n que se realiza con biomateriales. Los retos espec\u00edficos asociados a los biomateriales han requerido el desarrollo de ensayos mec\u00e1nicos capaces de controlar con precisi\u00f3n la carga en materiales extremadamente blandos o fr\u00e1giles. Adem\u00e1s, se necesitan m\u00faltiples instrumentos para realizar diversos ensayos mec\u00e1nicos que ahora pueden llevarse a cabo en un solo sistema. La nanoindentaci\u00f3n proporciona una amplia gama de mediciones con una resoluci\u00f3n precisa a cargas controladas a nanoescala para aplicaciones sensibles.<\/p><p>\u00a0<\/p><p>\u00a0<\/p><p style=\"text-align: left; color: #1b96cf; font-size: 24px;\">Objetivo de medici\u00f3n<u><br \/><\/u><\/p><p>En esta aplicaci\u00f3n, Nanovea <a href=\"https:\/\/nanovea.com\/mechanical-testers\/\">Comprobador mec\u00e1nico<\/a>, en modo nanoindentaci\u00f3n, se utiliza para estudiar la dureza y el m\u00f3dulo el\u00e1stico de la dentina, la caries y la pulpa de un diente. El aspecto m\u00e1s cr\u00edtico de las pruebas de nanoindentaci\u00f3n es asegurar la muestra. En este caso, tomamos un diente cortado y lo montamos con epoxi, dejando expuestas las tres \u00e1reas de inter\u00e9s para la prueba.<\/p><p>\u00a0<\/p><p style=\"text-align: center;\"><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/Updated-picture-measuring-sample.png\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-7727\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/Updated-picture-measuring-sample.png\" alt=\"\" width=\"558\" height=\"452\" \/><\/a><\/p><p style=\"text-align: center;\"><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/test-conditions-table.png\"><img decoding=\"async\" class=\"wp-image-7650 aligncenter\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/test-conditions-table.png\" alt=\"\" width=\"526\" height=\"230\" \/><\/a><\/p><p>\u00a0<\/p><p style=\"text-align: left; color: #1b96cf; font-size: 24px;\">Resultados y debate<u><br \/><\/u><\/p><p>Esta secci\u00f3n incluye una tabla resumen que compara los principales resultados num\u00e9ricos de las diferentes muestras, seguida de la lista completa de resultados, incluyendo cada indentaci\u00f3n realizada, acompa\u00f1ada de micrograf\u00edas de la indentaci\u00f3n, cuando est\u00e1n disponibles. Estos resultados completos presentan los valores medidos de dureza y m\u00f3dulo de Young como la profundidad de penetraci\u00f3n con sus promedios y desviaciones est\u00e1ndar. Debe tenerse en cuenta que pueden producirse grandes variaciones en los resultados en caso de que la rugosidad de la superficie se encuentre en el mismo rango de tama\u00f1o que la indentaci\u00f3n.<\/p><p>Cuadro resumen de los principales resultados num\u00e9ricos:<\/p><p>\u00a0<\/p><div style=\"text-align: center;\"><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/results-1.png\"><img decoding=\"async\" class=\"alignnone size-full wp-image-7652\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/results-1.png\" alt=\"\" width=\"997\" height=\"777\" \/><\/a><\/div><div style=\"text-align: center;\"><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/results-2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7654\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/results-2.png\" alt=\"\" width=\"558\" height=\"668\" \/><\/a><\/div><div style=\"text-align: center;\"><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/results-3.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-7656 aligncenter\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/results-3.png\" alt=\"\" width=\"543\" height=\"679\" \/><\/a><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/results-4.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7658\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/results-4.png\" alt=\"\" width=\"553\" height=\"680\" \/><\/a><\/div><p>\u00a0<\/p><p style=\"text-align: left; color: #1b96cf; font-size: 24px;\">Conclusi\u00f3n<\/p><p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/tooth-hardness-cop.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7648\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2017\/12\/tooth-hardness-cop.png\" alt=\"\" width=\"1920\" height=\"776\" \/><\/a><\/p><p>En conclusi\u00f3n, hemos demostrado c\u00f3mo el Nanovea Mechanical Tester, en modo nanoindentaci\u00f3n, proporciona una medici\u00f3n precisa de las propiedades mec\u00e1nicas de un diente. Los datos pueden utilizarse en el desarrollo de empastes que se adapten mejor a las caracter\u00edsticas mec\u00e1nicas de un diente real. La capacidad de posicionamiento del Nanovea Mechanical Tester permite realizar un mapeo completo de la dureza de los dientes en las distintas zonas.<\/p><p>Utilizando el mismo sistema, es posible probar la resistencia a la fractura del material dental con cargas m\u00e1s elevadas, de hasta 200 N. Se puede realizar una prueba de carga multiciclo en materiales m\u00e1s porosos para evaluar el nivel de elasticidad restante. El uso de una punta de diamante cil\u00edndrica plana puede proporcionar informaci\u00f3n sobre el l\u00edmite el\u00e1stico en cada zona. Adem\u00e1s, con el \u201can\u00e1lisis mec\u00e1nico din\u00e1mico\u201d (DMA), se pueden evaluar las propiedades viscoel\u00e1sticas, incluidos los m\u00f3dulos de p\u00e9rdida y almacenamiento.<\/p><p>El nanom\u00f3dulo Nanovea es ideal para estas pruebas porque utiliza una respuesta de retroalimentaci\u00f3n \u00fanica para controlar con precisi\u00f3n la carga aplicada. Gracias a ello, el nanom\u00f3dulo tambi\u00e9n se puede utilizar para realizar pruebas precisas de nanoara\u00f1azos. El estudio de la resistencia al rayado y al desgaste de los materiales dentales y de obturaci\u00f3n aumenta la utilidad general del probador mec\u00e1nico. El uso de una punta afilada de 2 micras para comparar cuantitativamente el desgaste de los materiales de obturaci\u00f3n permitir\u00e1 predecir mejor el comportamiento en aplicaciones reales. Las pruebas de desgaste multipaso o de desgaste rotativo directo tambi\u00e9n son pruebas comunes que proporcionan informaci\u00f3n importante sobre la viabilidad a largo plazo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-166b26b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"166b26b\" data-element_type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-347f30c\" data-id=\"347f30c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a94b471 elementor-widget elementor-widget-heading\" data-id=\"a94b471\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><b>AHORA, HABLEMOS DE SU SOLICITUD<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-81588e3 live-chat elementor-align-center elementor-widget elementor-widget-button\" data-id=\"81588e3\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/nanovea.com\/contact\/live-chat\/\" id=\"live-chat\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">CHAT EN VIVO<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Importance of Nanoindentation for Bio Materials \u00a0With many traditional mechanical tests (Hardness, Adhesion, Compression, Puncture, Yield Strength, etc.), today\u2019s quality control environments with advanced sensitive materials, from gels to brittle materials, now require greater precision and reliability control. Traditional mechanical instrumentation fails to provide the sensitive load control and resolution required; designed to be used [&hellip;]<\/p>","protected":false},"author":1,"featured_media":11702,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"footnotes":""},"categories":[7,338,349,337],"tags":[],"class_list":["post-7623","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","category-indentation-hardness-elastic","category-laboratory-testing","category-mechanical-testing"],"_links":{"self":[{"href":"https:\/\/nanovea.com\/es\/wp-json\/wp\/v2\/posts\/7623","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nanovea.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nanovea.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nanovea.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/nanovea.com\/es\/wp-json\/wp\/v2\/comments?post=7623"}],"version-history":[{"count":47,"href":"https:\/\/nanovea.com\/es\/wp-json\/wp\/v2\/posts\/7623\/revisions"}],"predecessor-version":[{"id":23486,"href":"https:\/\/nanovea.com\/es\/wp-json\/wp\/v2\/posts\/7623\/revisions\/23486"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nanovea.com\/es\/wp-json\/wp\/v2\/media\/11702"}],"wp:attachment":[{"href":"https:\/\/nanovea.com\/es\/wp-json\/wp\/v2\/media?parent=7623"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nanovea.com\/es\/wp-json\/wp\/v2\/categories?post=7623"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nanovea.com\/es\/wp-json\/wp\/v2\/tags?post=7623"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}