{"id":8484,"date":"2020-07-01T18:25:00","date_gmt":"2020-07-01T18:25:00","guid":{"rendered":"https:\/\/nanovea.com\/?p=8484"},"modified":"2023-11-08T23:06:07","modified_gmt":"2023-11-08T23:06:07","slug":"dental-tools-dimensional-and-surface-roughness-analysis","status":"publish","type":"post","link":"https:\/\/nanovea.com\/de\/dental-tools-dimensional-and-surface-roughness-analysis\/","title":{"rendered":"Zahn\u00e4rztliche Werkzeuge: Analyse der Dimensionen und der Oberfl\u00e4chenrauhigkeit"},"content":{"rendered":"<p><a href=\"https:\/\/nanovea.com\/App-Notes\/Dental-Tools-Dimensional-and-Surface-Roughness-Analysis.pdf&quot;\" target=\"_blank\" rel=\"noopener\"><br \/>\n<img decoding=\"async\" class=\"alignright\" style=\"width: 200px;\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/DOWNLOAD-PDF-BUTTON-A-s.png\" \/><br \/>\n<\/a><\/p>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<h2><em><strong>EINF\u00dcHRUNG<\/strong><\/em><\/h2>\n<p>&nbsp;<\/p>\n<p>Pr\u00e4zise Abmessungen und optimale Oberfl\u00e4chenrauheit sind f\u00fcr die Funktionalit\u00e4t von Dentalschrauben von entscheidender Bedeutung. Viele Abmessungen von Dentalschrauben erfordern eine hohe Pr\u00e4zision wie Radien, Winkel, Abst\u00e4nde und Stufenh\u00f6hen. Das Verst\u00e4ndnis der lokalen Oberfl\u00e4chenrauheit ist auch f\u00fcr jedes medizinische Werkzeug oder Teil, das in den menschlichen K\u00f6rper eingef\u00fchrt wird, \u00e4u\u00dferst wichtig, um die Gleitreibung zu minimieren.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><em><strong>BER\u00dcHRUNGSLOSE PROFILOMETRIE ZUR DIMENSIONALSTUDIE<\/strong><\/em><\/h2>\n<p>&nbsp;<\/p>\n<p>Nanovea <a href=\"https:\/\/nanovea.com\/profilometers\/\">Ber\u00fchrungslose 3D-Profiler<\/a> Verwenden Sie eine auf chromatischem Licht basierende Technologie, um jede Materialoberfl\u00e4che zu messen: transparent, undurchsichtig, spiegelnd, diffus, poliert oder rau. Im Gegensatz zu einer Touch-Probe-Technik kann die ber\u00fchrungslose Technik innerhalb enger Bereiche messen und verursacht keine intrinsischen Fehler aufgrund von Verformungen, die durch das Dr\u00fccken der Spitze auf ein weicheres Kunststoffmaterial verursacht werden. Die auf chromatischem Licht basierende Technologie bietet im Vergleich zur Fokusvariationstechnologie auch \u00fcberlegene Seiten- und H\u00f6hengenauigkeiten. Nanovea Profiler k\u00f6nnen gro\u00dfe Fl\u00e4chen ohne N\u00e4hte direkt scannen und die L\u00e4nge eines Teils in wenigen Sekunden profilieren. Aufgrund der F\u00e4higkeit des Profilers, Oberfl\u00e4chen zu messen, ohne dass komplexe Algorithmen die Ergebnisse manipulieren, k\u00f6nnen Oberfl\u00e4chenmerkmale im Nano- bis Makrobereich und gro\u00dfe Oberfl\u00e4chenwinkel gemessen werden.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><strong><em>MESSZIEL<\/em><\/strong><\/h2>\n<p>&nbsp;<\/p>\n<p>In dieser Anwendung wurde der optische Profiler ST400 von Nanovea verwendet, um eine Zahnschraube entlang von Flach- und Gewindemerkmalen in einer einzigen Messung zu messen. Aus der flachen Fl\u00e4che wurde die Oberfl\u00e4chenrauheit berechnet und verschiedene Abmessungen der Gewindemerkmale bestimmt.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Measurement-Objective-OLD.jpg\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-8505\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Measurement-Objective-OLD.jpg\" alt=\"Qualit\u00e4tskontrolle von Zahnschrauben\" width=\"1319\" height=\"665\" \/><\/a><\/p>\n<div><\/div>\n<h6 style=\"text-align: center;\"><em>Probe einer Zahnschraube, analysiert von <strong>NANOVEA<\/strong> Optischer Profiler.<\/em><\/h6>\n<p>&nbsp;<\/p>\n<div style=\"text-align: center;\">\n<p><img decoding=\"async\" class=\"wp-image-8514 size-full\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/dental-implant-screw-analyzed-s.jpg\" alt=\"\" width=\"200\" height=\"83\" \/><\/p>\n<h6 class=\"mceTemp\" style=\"text-align: center;\"><i>Zahnschraubenprobe analysiert.<\/i><\/h6>\n<\/div>\n<p>&nbsp;<\/p>\n<h2><em><strong>ERGEBNISSE<\/strong><\/em><\/h2>\n<p>&nbsp;<\/p>\n<p><strong><em>3D-Oberfl\u00e4che<\/em><\/strong><\/p>\n<p>Die 3D-Ansicht und die Falschfarbenansicht der Zahnschraube zeigen einen flachen Bereich mit auf beiden Seiten beginnendem Gewinde. Es bietet Benutzern ein einfaches Werkzeug, um die Morphologie der Schraube aus verschiedenen Winkeln direkt zu beobachten. Der flache Bereich wurde aus dem vollst\u00e4ndigen Scan extrahiert, um seine Oberfl\u00e4chenrauheit zu messen.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-13.png\"><img decoding=\"async\" class=\"size-full wp-image-8525 aligncenter\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-13.png\" alt=\"\" width=\"996\" height=\"746\" \/><\/a><\/p>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-14.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8526 aligncenter\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-14.png\" alt=\"\" width=\"907\" height=\"622\" \/><\/a><\/p>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-15.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8527 aligncenter\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-15.png\" alt=\"\" width=\"1158\" height=\"650\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><em><strong>2D-Oberfl\u00e4chenanalyse<\/strong><\/em><\/p>\n<p>Au\u00dferdem k\u00f6nnen Linienprofile aus der Oberfl\u00e4che extrahiert werden, um eine Querschnittsansicht der Schraube zu zeigen. Die Konturanalyse und Stufenh\u00f6henstudien wurden verwendet, um genaue Abmessungen an einer bestimmten Stelle der Schraube zu messen.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-16.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8528 aligncenter\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-16.png\" alt=\"\" width=\"964\" height=\"854\" \/><\/a><\/p>\n<div><\/div>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-17.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8529 aligncenter\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-17.png\" alt=\"\" width=\"1117\" height=\"634\" \/><\/a><\/p>\n<div><\/div>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-18.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8530 aligncenter\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-QC-18.png\" alt=\"\" width=\"1102\" height=\"697\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-Profilometer.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-8532 aligncenter\" src=\"https:\/\/nanovea.com\/wp-content\/uploads\/2020\/06\/Dental-Screw-Profilometer.jpg\" alt=\"\" width=\"1000\" height=\"561\" \/><\/a><\/p>\n<div><\/div>\n<h2><em><strong>SCHLUSSFOLGERUNG<\/strong><\/em><\/h2>\n<p>&nbsp;<\/p>\n<p>In dieser Anwendung haben wir die F\u00e4higkeit des Nanovea 3D Non-Contact Profiler demonstriert, die lokale Oberfl\u00e4chenrauheit pr\u00e4zise zu berechnen und gro\u00dfdimensionale Merkmale in einem einzigen Scan zu messen.<\/p>\n<p>Die Daten zeigen eine lokale Oberfl\u00e4chenrauheit von 0,9637 \u03bcm. Der Radius der Schraube zwischen den Gewindeg\u00e4ngen betrug 1,729 mm und die Gewindeg\u00e4nge hatten eine durchschnittliche H\u00f6he von 0,413 mm. Der durchschnittliche Winkel zwischen den Gewindeg\u00e4ngen wurde mit 61,3\u00b0 ermittelt.<\/p>\n<p>Die hier gezeigten Daten stellen nur einen Teil der in der Analysesoftware verf\u00fcgbaren Berechnungen dar.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">Vorbereitet von<br \/>\nDuanjie Li, PhD., Jonathan Thomas und Pierre Leroux<\/p>","protected":false},"excerpt":{"rendered":"<p>INTRODUCTION &nbsp; Having precise dimensions and optimal surface roughness are vital to the functionality of dental screws. Many dental screw dimensions require high precision such as radii, angles, distances, and step heights. Understanding local surface roughness is also highly important for any medical tool or part being inserted inside the human body to minimize sliding [&hellip;]<\/p>","protected":false},"author":7,"featured_media":11679,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"footnotes":""},"categories":[7,349,350,351,335],"tags":[],"class_list":["post-8484","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","category-laboratory-testing","category-profilometry-geometry-shape","category-profilometry-roughness-finish","category-profilometry-testing"],"_links":{"self":[{"href":"https:\/\/nanovea.com\/de\/wp-json\/wp\/v2\/posts\/8484","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nanovea.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nanovea.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nanovea.com\/de\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/nanovea.com\/de\/wp-json\/wp\/v2\/comments?post=8484"}],"version-history":[{"count":67,"href":"https:\/\/nanovea.com\/de\/wp-json\/wp\/v2\/posts\/8484\/revisions"}],"predecessor-version":[{"id":23327,"href":"https:\/\/nanovea.com\/de\/wp-json\/wp\/v2\/posts\/8484\/revisions\/23327"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nanovea.com\/de\/wp-json\/wp\/v2\/media\/11679"}],"wp:attachment":[{"href":"https:\/\/nanovea.com\/de\/wp-json\/wp\/v2\/media?parent=8484"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nanovea.com\/de\/wp-json\/wp\/v2\/categories?post=8484"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nanovea.com\/de\/wp-json\/wp\/v2\/tags?post=8484"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}